摘要
Conventional transmission pulse oximetry is a noninvasive technique for the continuous monitoring of arterial oxygen saturation (SaO(2)) from peripheral vascular beds;such as the finger tip or earlobe. In this paper we propose to exploit the unique transparency of the ocular media to make reflectance pulse oximetry measurements on the retinal fundus. This technique potentially offers significant advantages over conventional pulse oximetry, primarily the ability to monitor cerebral, as opposed to peripheral, oxygen saturation. We have developed an in vitro system to simulate the retinal circulation and ocular optics. This system consists of a flexible cuvette located in a model eye and an extracorporeal blood circuit to simulate arterial blood flow. The system was used to investigate the relationship between SaO(2) and the R/IR ratio in reflectance pulse oximetry. To enable in vivo measurements to be made, we also modified a standard haptic contact lens to hold the pulse oximeter probe in front of the pupil. In a preliminary study, the lens was fitted to an awake volunteer and cardiac-synchronous signals were detected by the retinal pulse oximeter.
引用
收藏
页码:817 / 823
页数:7
相关论文
共 20 条
  • [1] MULTIPLE-SCATTERING ANALYSIS OF RETINAL BLOOD OXIMETRY
    COHEN, AJ
    LAING, RA
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1976, 23 (05) : 391 - 400
  • [2] PULSE OXIMETRY - THEORETICAL AND EXPERIMENTAL-MODELS
    DEKOCK, JP
    TARASSENKO, L
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (03) : 291 - 300
  • [3] INVITRO INVESTIGATION OF THE FACTORS AFFECTING PULSE OXIMETRY
    DEKOCK, JP
    TARASSENKO, L
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (01): : 61 - 66
  • [4] DEKOCK JP, 1991, THESIS U OXFORD UK
  • [5] NONINVASIVE TECHNIQUE FOR OXIMETRY OF BLOOD IN RETINAL-VESSELS
    DELORI, FC
    [J]. APPLIED OPTICS, 1988, 27 (06) : 1113 - 1125
  • [6] OXYGEN AND CO2 TRANSFER OF A POLYPROPYLENE DIMPLED MEMBRANE LUNG WITH VARIABLE SECONDARY FLOWS
    DORRINGTON, KL
    RALPH, ME
    BELLHOUSE, BJ
    GARDAZ, JP
    SYKES, MK
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1985, 7 (02): : 89 - 99
  • [7] ADAPTATION OF PULSE OXIMETRY FOR FETAL MONITORING DURING LABOR
    GARDOSI, JO
    SCHRAM, CM
    SYMONDS, EM
    [J]. LANCET, 1991, 337 (8752) : 1265 - 1267
  • [8] A STUDY OF RETINAL VENOUS BLOOD OXYGEN SATURATION IN HUMAN SUBJECTS BY PHOTOGRAPHIC MEANS
    HICKAM, JB
    FRAYSER, R
    ROSS, JC
    [J]. CIRCULATION, 1963, 27 (03) : 375 - &
  • [9] HICKHAM JB, 1959, PHOTOGRAPHIC MEASURE, P58
  • [10] FETAL MONITORING WITH PULSE OXIMETRY
    JOHNSON, N
    JOHNSON, VA
    FISHER, J
    JOBBINGS, B
    BANNISTER, J
    LILFORD, RJ
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1991, 98 (01): : 36 - 41