An electron microprobe was used to investigate the composition and microstructure of commercially available, and experimental dental amalgam alloy particles of .apprx. Ag-Cu eutectic composition. The method of alloy and amalgam specimen preparation and the technique used in microprobe analysis were briefly outlined. The dispersant particles in 1 commercial alloy were of Ag-Cu eutectic composition (28.1% Cu), in another commercial alloy they were Cu-rich (31% Cu). Although the dispersant particles were predominantly of uniform appearance, there was evidence in some particles of an internal structure pattern, small spherical inclusions or voids. The possible composition of the Cu-rich inclusions was investigated using particles from an experimental alloy of .apprx. Ag-Cu eutectic composition.
引用
收藏
页码:571 / 578
页数:8
相关论文
共 18 条
[1]  
ASGAR K, 1971, J DENT RES, V50, P56
[2]   STRENGTH OF 15 AMALGAM ALLOYS [J].
BRYANT, RW .
AUSTRALIAN DENTAL JOURNAL, 1979, 24 (04) :244-252
[3]  
BRYANT RW, 1980, AUST DENT J, V25, P7, DOI 10.1111/j.1834-7819.1980.tb03656.x
[4]  
BRYANT RW, 1982, THESIS U SYDNEY SYDN, P236
[5]  
Duncumb P., 1968, Quantitative electron probe microanalysis, NBS Special Publication 298, P133
[6]  
GIBLIN JP, 1979, J DENTAL RES D, V58, P2243
[7]  
Innes D.B.K., 1963, CAN DENT ASSOC J, V29, P587
[8]  
LASWELL HR, 1980, OPER DENT, V5, P49
[9]  
MAHLER DB, 1975, J DENT RES, V54, P218
[10]   MARGINAL FRACTURE OF AMALGAM RESTORATIONS [J].
MAHLER, DB ;
TERKLA, LG ;
VANEYSDE.J .