RADIATION-DOSE RATES FROM PEDIATRIC-PATIENTS UNDERGOING TC-99M INVESTIGATIONS

被引:0
作者
MOUNTFORD, PJ
ODOHERTY, MJ
HARDING, LK
THOMSON, WH
CARTER, NJ
BRAY, D
PAUL, C
BATCHELOR, S
机构
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Infants or children undergoing nuclear medicine investigations may subsequently come into close contact with nurses or parents responsible for their care. In order to estimate the radiation dose to these individuals, and to formulate appropriate recommendations, dose rates were measured at distances of 0.1, 0.5 and 1.0 m from 148 paediatric patients who had undergone one of 12 Tc-99(m) studies. The maximum dose rates of 70, 14 and 5-mu-Sv h-1 at these distances were not greater than the corresponding maximum values found in an earlier study of adult patients. However, the maximum dose rates per unit activity of 0.5, 0.2 and 0.1-mu-Sv h-1 MBq-1 were greater than the corresponding maximum Tc-99(m) adult values, consistent with a general increase of dose rate per unit activity with decrease of body weight observed in the paediatric measurements. A parent caring for and feeding a young infant is most unlikely to receive a dose equivalent of 1 mSv, and a nurse attending to one young radioactive patient is most unlikely to receive a dose equivalent in a working day of 60-mu-Sv. The data obtained should allow radiation doses to be estimated and appropriate recommendations to be formulated for other circumstances, including any future legislative changes in dose limits or derived levels.
引用
收藏
页码:709 / 718
页数:10
相关论文
共 50 条
[41]   RADIATION-DOSE TO HANDS FROM HANDLING MO-99-TC-99M GENERATORS MEASURED BY MEANS OF UVVVR FINGER DOSIMETERS [J].
HUSAK, V ;
HAVLIK, J .
JADERNA ENERGIE, 1980, 26 (12) :465-466
[42]   RADIATION ABSORBED DOSE TO THE LENS IN DACRYOSCINTIGRAPHY WITH (TCO4-)-TC-99M [J].
ROBERTSON, JS ;
BROWN, ML ;
COLVARD, DM .
RADIOLOGY, 1979, 133 (03) :747-750
[43]   RADIATION EXPOSURE TO PERSONNEL HANDLING TC-99M [J].
DAMM, DW ;
WOLFF, J .
JOURNAL OF NUCLEAR MEDICINE, 1970, 11 (06) :408-&
[44]   INVESTIGATIONS INTO THE MECHANISM OF TC-99M TRANSCHELATION IN TUMOR FROM ANTIBODIES TO CYSTEINE [J].
RUSCHKOWSKI, M ;
FOGARASI, M ;
VIRZI, F ;
WINNARD, P ;
HNATOWICH, DJ .
JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) :P105-P105
[45]   Body morphometry appropriate computational phantoms for dose and risk optimization in pediatric renal imaging with Tc-99m DMSA and Tc-99m MAG3 [J].
Brown, Justin L. ;
Sexton-Stallone, Briana ;
Li, Ye ;
Frey, Eric C. ;
Treves, S. Ted ;
Fahey, Frederic H. ;
Plyku, Donika ;
Cao, Xinhua ;
Sgouros, George ;
Bolch, Wesley E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23)
[46]   CALCULATION OF THE RADIATION-DOSE BY THIOGLUCOSE-TC-99M ACCORDING TO THE EXPANDED MIRD-CONCEPTION [J].
TAUTZ, M ;
ERTL, S ;
DECKART, H .
RADIOBIOLOGIA-RADIOTHERAPIA, 1979, 20 (06) :785-790
[47]   THE DETERMINATION OF RELATIVE RENAL-FUNCTION IN A PEDIATRIC POPULATION USING TC-99M DTPA AND TC-99M DMSA [J].
ROSEN, PR ;
KURUC, A ;
TREVES, ST .
JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (05) :P10-P10
[48]   INVESTIGATIONS OF ASCORBATE FOR DIRECT LABELING OF ANTIBODIES WITH TC-99M [J].
HNATOWICH, DJ ;
VIRZI, F ;
WINNARD, P ;
FOGARASI, M ;
RUSCKOWSKI, M .
JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (01) :127-134
[49]   ABSORBED RADIATION-DOSE TO HUMANS FROM TECHNETIUM-99M-TEBOROXIME [J].
NARRA, RK ;
FELD, T ;
NUNN, AD .
JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (01) :88-93
[50]   Sources of variability of count rate from patients undergoing cardiac Tc-99m Tetrofosmin examinations: Effect of administered radioactive dose [J].
Nguyen, Vincent ;
Pavlicek, William ;
Unzek, Samuel ;
Tollefson, Chris .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55