RADIATION-DOSE RATES FROM PEDIATRIC-PATIENTS UNDERGOING TC-99M INVESTIGATIONS

被引:0
作者
MOUNTFORD, PJ
ODOHERTY, MJ
HARDING, LK
THOMSON, WH
CARTER, NJ
BRAY, D
PAUL, C
BATCHELOR, S
机构
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Infants or children undergoing nuclear medicine investigations may subsequently come into close contact with nurses or parents responsible for their care. In order to estimate the radiation dose to these individuals, and to formulate appropriate recommendations, dose rates were measured at distances of 0.1, 0.5 and 1.0 m from 148 paediatric patients who had undergone one of 12 Tc-99(m) studies. The maximum dose rates of 70, 14 and 5-mu-Sv h-1 at these distances were not greater than the corresponding maximum values found in an earlier study of adult patients. However, the maximum dose rates per unit activity of 0.5, 0.2 and 0.1-mu-Sv h-1 MBq-1 were greater than the corresponding maximum Tc-99(m) adult values, consistent with a general increase of dose rate per unit activity with decrease of body weight observed in the paediatric measurements. A parent caring for and feeding a young infant is most unlikely to receive a dose equivalent of 1 mSv, and a nurse attending to one young radioactive patient is most unlikely to receive a dose equivalent in a working day of 60-mu-Sv. The data obtained should allow radiation doses to be estimated and appropriate recommendations to be formulated for other circumstances, including any future legislative changes in dose limits or derived levels.
引用
收藏
页码:709 / 718
页数:10
相关论文
共 50 条
[31]   SOLVENT-EXTRACTION TECHNOLOGY OF MO-99 TC-99M GENERATOR SYSTEM .2. RADIATION-DOSE AND PERSONNEL EXPOSURE CONSIDERATIONS [J].
NORONHA, OPD .
ISOTOPENPRAXIS, 1986, 22 (02) :58-62
[32]   Radiation adaptive response in lymphocytes of patients undergoing Tc-99m Sestamibi myocardial imaging. [J].
Bom, HS ;
Min, JJ ;
Jeong, HJ ;
Song, HC ;
Kim, JY .
JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) :314P-314P
[33]   RADIATION-DOSE TO BLADDER WALL FOLLOWING THE ADMINISTRATION OF TC-99M-LABELED MICROSPHERES AND TC-99M-LABELED DTPA [J].
SMITH, T .
HEALTH PHYSICS, 1981, 41 (05) :777-780
[34]   DOSIMETRY OF SWALLOWED NONABSORBED TC-99M-RADIOPHARMACEUTICALS IN PEDIATRIC-PATIENTS [J].
WYNCHANK, S ;
MANN, MD ;
GONIN, R .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1990, 16 (4-6) :337-343
[35]   RADIATION-DOSE CALCULATIONS FOR BONE SCANNING WITH PHOSPHATE-TC-99M COMPOUNDS IN CHILDREN [J].
SCHUMICHEN, C ;
WUST, H ;
HOFFMANN, G .
ANNALES DE RADIOLOGIE, 1980, 23 (02) :115-119
[36]   EFFECT OF MILKING EFFICIENCY ON TC-99 CONTENT OF TC-99M DERIVED FROM TC-99M GENERATORS [J].
BONNYMAN, J .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1983, 13 (06) :661-661
[37]   EFFECT OF MILKING EFFICIENCY ON TC-99 CONTENT OF TC-99M DERIVED FROM TC-99M GENERATORS [J].
BONNYMAN, J .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1983, 34 (06) :901-906
[38]   Radioluminescence from Tc-99m in glass predicts local dose [J].
Ackerman, Nicole L. ;
Boschi, Federico ;
Spinelli, Antonello E. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 42 :112-115
[39]   PLASMA-CLEARANCE OF TC-99M DTPA (CL-TC) FOR EVALUATING GLOMERULAR-FILTRATION RATE (GFR) IN PEDIATRIC-PATIENTS [J].
MANEVAL, DC ;
SUNDERLAND, M ;
MAGILL, HL ;
RODMAN, JH .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1990, 47 (02) :187-187
[40]   TC-99M HMPAO SPECT IN PEDIATRIC MIGRAINE [J].
BATTISTELLA, PA ;
RUFFILLI, R ;
POZZA, FD ;
PITASSI, I ;
CASARA, GL ;
BONIVER, C ;
SUPPIEJ, A ;
BENDAGLI, B ;
CONDINI, A .
HEADACHE, 1990, 30 (10) :646-649