Planar scintigrams are deconvolved with a point spread function using the maximum entropy method with the aim of improving image quality. The technique requires the specification of several parameters. These are related to the level of noise present in the data and our a priori knowledge of the object imaged. The performance of the technique is tested for a wide range of these parameters using images of a Williams phantom in scattering material and a figure of merit, derived from the detectability of the smallest cold spot, is calculated. For close to optimal values of the parameters a factor of two improvement in the figure is found. A processed bone image shows improved contrast and resolution. Maximum entropy processing could be used to increase image quality or allow comparable image quality with reduced imaging time or patient dose.
引用
收藏
页码:153 / 162
页数:10
相关论文
共 27 条
  • [1] CONSTRAINED OPTIMIZATION AND ITS APPLICATION TO SCINTIGRAPHY
    BOARDMAN, AK
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (02) : 363 - 371
  • [2] USE OF THE GEOMETRIC MEAN OF OPPOSING PLANAR PROJECTIONS IN PRERECONSTRUCTION RESTORATION OF SPECT IMAGES
    BOULFELFEL, D
    RANGAYYAN, RM
    HAHN, LJ
    KLOIBER, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) : 1915 - 1929
  • [3] PRERECONSTRUCTION RESTORATION OF MYOCARDIAL SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY IMAGES
    BOULFELFEL, D
    RANGAYYAN, RM
    HAHN, LJ
    KLOIBER, R
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) : 336 - 341
  • [4] BRYAN RK, 1980, MON NOT R ASTRON SOC, V191, P69
  • [5] 2 ITERATIVE IMAGE-RESTORATION ALGORITHMS WITH APPLICATIONS TO NUCLEAR-MEDICINE
    CHARALAMBOUS, C
    GHADDAR, FK
    KOURIS, K
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) : 2 - 8
  • [6] CHARTER M, 1987, J PHARMACOKIN BIOPHA, V16, P645
  • [7] DANIELL G, 1991, MAXIMUM ENTROPY ACTI, pCH1
  • [8] MAXIMUM-ENTROPY ALGORITHM APPLIED TO IMAGE-ENHANCEMENT
    DANIELL, GJ
    GULL, SF
    [J]. IEE PROCEEDINGS-E COMPUTERS AND DIGITAL TECHNIQUES, 1980, 127 (05): : 170 - 172
  • [9] A GENERAL SOFTWARE PACKAGE FOR THE HANDLING OF MEDICAL IMAGES
    FLEMING, JS
    BRITTEN, AJ
    PERRING, S
    KEEN, AC
    HOWLETT, PJ
    [J]. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1991, 15 (4-5) : 162 - 169
  • [10] Gonzalez R. C., 1987, DIGITAL IMAGE PROCES