Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system

被引:18
|
作者
Wang, Li-Juan [1 ,2 ]
Thng, Yu-Hai [2 ]
Liu, Yang-Hao [2 ]
机构
[1] Xi An Jiao Tong Univ, Med Sch, Xian 710061, Peoples R China
[2] Xi An Jiao Tong Univ, Inst Analyt Sci, Xian 710061, Peoples R China
关键词
chemiluminescence; KMnO4; loxoprofen; naproxen;
D O I
10.1016/S2095-1779(11)70009-0
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A novel flow injection chemiluminescence (CL) method for the determination of loxoprofen and naproxen was proposed based on the CL system of KMnO4 and Na2SO3 in acid media. The CL intensity of KMnO4 - Na2SO3 was greatly enhanced in the presence of loxoprofen and naproxen. The mechanism of the CL reaction was studied by the kinetic process and UV-vis absorption and the conditions were optimized. Under optimized conditions, the CL intensity was linear with loxoprofen and naproxen concentration in the range of 7.0 X 10(-8) - 1.0 x 10(-5) g/mL and 2.0 x 10(-7) - 4.0 X 10(-5) g/mL with the detection limit of 2.0 x 10(-8) g/mL and 3.0 x 10(-8) g/mL (S/N = 3), respectively. The relative standard deviations were 2.39% and 1.37% for 5.0 x 10(-7) g/mL naproxen and 5.0 x 10(-7) g/mL loxoprofen (n = 10), respectively. The proposed method was satisfactorily applied to the determination of loxoprofen and naproxen in pharmaceutical preparations.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 50 条
  • [21] Flow injection chemiluminescence determination of ethamsylate based on permanganate oxidation
    Du, JX
    Li, YH
    Tang, Y
    Lu, JR
    ANALYTICAL LETTERS, 2002, 35 (03) : 463 - 472
  • [22] Flow injection-chemiluminescence determination of dopamine using potassium permanganate and formaldehyde system
    Wabaidur, Saikh Mohammad
    Alothman, Zeid Abdullah
    Alam, Seikh Mafiz
    Lee, Sang Hak
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2012, 96 : 221 - 225
  • [23] Flow injection-chemiluminescence determination of amoxycillin using potassium permanganate and formaldehyde system
    Cao, W
    Yang, JH
    Sun, CX
    Chen, YJ
    Ga, QF
    LUMINESCENCE, 2005, 20 (01) : 20 - 24
  • [24] Flow injection-chemiluminescence determination of phenol using potassium permanganate and formaldehyde system
    Cao, Wei
    Mu, Xuemin
    Yang, Jinghe
    Shi, Wenbo
    Zheng, Yongcun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2007, 66 (01) : 58 - 62
  • [25] Flow-injection chemiluminescence determination of papaverine using cerium(IV)-sulfite system
    Zhang, S
    Zhuang, YF
    Ju, HX
    ANALYTICAL LETTERS, 2004, 37 (01) : 143 - 155
  • [26] Determination of clomipramine by flow-injection analysis with acidic potassium permanganate-formic acid chemiluminescence detection
    Ji, Zhongling
    Yao, Xun
    Li, Jianguo
    LUMINESCENCE, 2011, 26 (06) : 741 - 746
  • [27] Determination of 5-hydroxytryptamine (serotonin) and related indoles by flow injection analysis with acidic potassium permanganate chemiluminescence detection
    Barnett, N. W.
    Hindson, B. J.
    Lewis, S. W.
    Analytica Chimica Acta, 362 (02):
  • [28] Determination of 5-hydroxytryptamine (serotonin) and related indoles by flow injection analysis with acidic potassium permanganate chemiluminescence detection
    Barnett, NW
    Hindson, BJ
    Lewis, SW
    ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) : 131 - 139
  • [29] Rapid flow injection method for the determination of sulfite in wine using the permanganate-luminol luminescence system
    Villar Navarrro, Mercedes
    Ramos Payan, Maria
    Bello Lopez, Miguel Angel
    Fernandez-Torres, Rut
    Callejon Mochon, Manuel
    TALANTA, 2010, 82 (05) : 2003 - 2006
  • [30] Insight into mechanism of arsanilic acid degradation in permanganate-sulfite system: Role of reactive species
    Shi, Zhenyu
    Jin, Can
    Zhang, Jing
    Zhu, Liang
    CHEMICAL ENGINEERING JOURNAL, 2019, 359 : 1463 - 1471