OPTIMIZATION OF ELECTRICAL CAPACITANCE TOMOGRAPHY SENSOR USING DESIGN OF EXPERIMENT METHOD

被引:0
作者
Osman-Ali, Najwan [1 ]
Mohamad-Saleh, Junita [1 ]
Abdul-Aziz, Zalina [1 ]
Talib, Hafizah [1 ]
机构
[1] Univ Sains Malaysia, Sch Elect & Elect Engn, Engn Campus, Perai 14300, Pulau Pinang, Malaysia
来源
JURNAL TEKNOLOGI | 2011年 / 55卷
关键词
Design of experiment; electrical capacitance tomography; sensor optimization;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper discusses the Design of Experiment (DOE) method to design an optimum Electrical Capacitance Tomography (ECT) sensor for gas-oil flows. The method has focused mainly on eliminating overshoots and undershoots in normalized ECT data. The DOE technique employed was an implementation of a 2(k) factorial design. ECT data based on ECT sensor parameters were used to evaluate the interaction among factors or inputs (i.e. ECT parameters) and the responses or outputs (i.e. normalized ECT data overshoot or undershoot) The results demonstrate the feasibility of using DOE to determine the interaction or influence of sensor parameters on the severity of normalized ECT data overshoots and undershoots and to facilitate the design of the most optimum ECT sensor for a particular application.
引用
收藏
页数:13
相关论文
共 12 条
[1]  
Ali Najwan Osman, 2008, P INT S INF TECHN 20, V1-4, P2393
[2]   Experimental design for simulation [J].
Kelton, WD ;
Barton, RR .
PROCEEDINGS OF THE 2003 WINTER SIMULATION CONFERENCE, VOLS 1 AND 2, 2003, :59-65
[3]   Sensitivity map generation in electrical capacitance tomography using mixed normalization models [J].
Kim, Yong Song ;
Lee, Seong Hun ;
Ijaz, Umer Zeeshan ;
Kim, Kyung Youn ;
Choi, Bong Yeol .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (07) :2092-2102
[4]   In vitro and in vivo activities offluoroquinolones against Aeromonas hydrophila [J].
Ko, WC ;
Chiang, SR ;
Lee, HC ;
Tang, HJ ;
Wang, YY ;
Chuang, YC .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2003, 47 (07) :2217-2222
[5]   Design of experiment (DOE) methods maximize information from a minimal number of animals in special cases of preclinical bioavailability testing [J].
Kuentz, M ;
Röthlisberger, D ;
Richter, W .
PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2003, 8 (04) :453-458
[6]  
Montgomery D.C., 2005, DESIGN ANAL EXPT, V5th
[8]  
Wang S., 2004, I ELECT ELECT ENG, P1252
[9]  
WILLIAM RA, 1995, PROCESS TOMOGRAPHY P
[10]   ELECTRICAL CAPACITANCE TOMOGRAPHY FOR FLOW IMAGING - SYSTEM MODEL FOR DEVELOPMENT OF IMAGE-RECONSTRUCTION ALGORITHMS AND DESIGN OF PRIMARY SENSORS [J].
XIE, CG ;
HUANG, SM ;
HOYLE, BS ;
THORN, R ;
LENN, C ;
SNOWDEN, D ;
BECK, MS .
IEE PROCEEDINGS-G CIRCUITS DEVICES AND SYSTEMS, 1992, 139 (01) :89-98