USE OF SCINTILLATION CAMERA AND 135XENON FOR STUDY OF TOPOGRAPHIC PULMONARY FUNCTION

被引:67
作者
NEWHOUSE, MT
WRIGHT, FJ
INGHAM, GK
ARCHER, NP
HUGHES, LB
HOPKINS, OL
机构
来源
RESPIRATION PHYSIOLOGY | 1968年 / 4卷 / 02期
关键词
!sup]135[!/sup]Xenon; Pulmonary blood flow distribution; Pulmonary ventilation distribution;
D O I
10.1016/0034-5687(68)90048-0
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A technique has been described which allows a quantitative, topographic evaluation of ventilation and perfusion distribution in the human lung, using the Anger scintillation camera to detect the distribution of the radioactive isotope, 135Xenon. The data obtained from four normal right and left lungs in seated, resting subjects, confirms the large (three to fourfold) apex to base perfusion gradient and the smaller (30%) ventilation gradient previously described by several authors. No significant horizontal gradient of either ventilation or perfusion could be detected. © 1968.
引用
收藏
页码:141 / &
相关论文
共 17 条
[1]  
ANGER HO, 1963, NUCLEONICS, V21, P56
[2]  
ARCHER NP, 1965, THESIS MCMASTER U
[3]   REGIONAL PULMONARY FUNCTION STUDIED WITH XENON133 [J].
BALL, WC ;
NEWSHAM, LGS ;
STEWART, PB ;
BATES, DV .
JOURNAL OF CLINICAL INVESTIGATION, 1962, 41 (03) :519-&
[4]  
BATES D V, 1962, Med Serv J Can, V18, P211
[5]  
BATES DV, 1950, CLIN SCI, V9, P17
[6]   THE INDEPENDENT YIELD OF XE-135 PRODUCED IN THE FISSION OF NATURAL URANIUM BY PILE NEUTRONS [J].
BROWN, F ;
YAFFE, L .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1953, 31 (03) :242-249
[7]   EFFECT OF ACCELERATION ON DISTRIBUTION OF PULMONARY BLOOD FLOW [J].
BRYAN, AC ;
MACNAMARA, WD ;
SIMPSON, J ;
WAGNER, HN .
JOURNAL OF APPLIED PHYSIOLOGY, 1965, 20 (06) :1129-+
[8]   EFFECT OF GRAVITY ON DISTRIBUTION OF PULMONARY VENTILATION [J].
BRYAN, AC ;
MILICEMI.J ;
PENGELLY, D .
JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (03) :778-&
[9]  
DOLFFUS RE, 1967, RESP PHYSL, V2, P234
[10]  
DOLLERY C. T., 1963, THORAX, V18, P316, DOI 10.1136/thx.18.4.316