PERFORMANCE-CHARACTERISTICS OF AN 8-RING WHOLE-BODY PET SCANNER

被引:206
|
作者
KOPS, ER [1 ]
HERZOG, H [1 ]
SCHMID, A [1 ]
HOLTE, S [1 ]
FEINENDEGEN, LE [1 ]
机构
[1] KAROLINSKA HOSP INST,DEPT NEURORADIOL,STOCKHOLM,SWEDEN
关键词
Attenuation Values; Emission computed tomography; Performance Evaluation; Techniques;
D O I
10.1097/00004728-199005000-00022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The technical characteristics of the multislice whole-body positron emission tomographic scanner (model PC4096-15WB Scanditronix) and its performance parameters are described. Spatial resolution at the center of the field of view was found to be 4.9 mm in-plane and 4.6 mm (cross slices) and 6.0 mm (direct slices) in the axial direction. The sensitivity for true and scattered coincidences is ~5,000 cps for direct slices and 7,100 cps for cross slices. At an activity concentration of 37 kBq/ml the system deadtime was ~5%. By measuring a uniform phantom with a cold cylindrical insert (5.0 cm diameter), the scatter fraction was found to be ~5%. The mean global uniformity over all 15 slices was 6.5%, whereas the local uniformity was found to be 4.3%. No systematic nonuniformities were observed. Finally, various methods for attenuation correction (transmission scan, contour finding, ellipse) were utilized to test their effects on the resulting reconstructed images. © 1990 Raven Press, Ltd., New York.
引用
收藏
页码:437 / 445
页数:9
相关论文
共 50 条
  • [1] PERFORMANCE-CHARACTERISTICS OF A WHOLE-BODY PET SCANNER
    DEGRADO, TR
    TURKINGTON, TG
    WILLIAMS, JJ
    STEARNS, CW
    HOFFMAN, JM
    COLEMAN, RE
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (08) : 1398 - 1406
  • [2] PERFORMANCE-CHARACTERISTICS OF A WHOLE-BODY POSITRON TOMOGRAPH
    SPINKS, TJ
    GUZZARDI, R
    BELLINA, CR
    JOURNAL OF NUCLEAR MEDICINE, 1988, 29 (11) : 1833 - 1841
  • [3] PERFORMANCE-CHARACTERISTICS OF A NEW CLINICAL WHOLE-BODY COUNTER
    WILLIAMS, JB
    MADDEN, JA
    EIKMAN, EA
    SOUTHERN MEDICAL JOURNAL, 1974, 67 (11) : 1388 - 1388
  • [4] TECHNICAL DESCRIPTION AND PERFORMANCE-CHARACTERISTICS OF A HUMAN WHOLE-BODY CALORIMETER
    SNELLEN, JW
    CHANG, KS
    SMITH, W
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1983, 21 (01) : 9 - 20
  • [5] DESIGN AND PERFORMANCE-CHARACTERISTICS OF A WHOLE-BODY POSITRON TRANSAXIAL TOMOGRAPH
    HOFFMAN, EJ
    PHELPS, ME
    MULLANI, NA
    HIGGINS, CS
    TERPOGOSSIAN, MM
    JOURNAL OF NUCLEAR MEDICINE, 1976, 17 (06) : 493 - 502
  • [6] Performance evaluation of a whole-body PET scanner using the NEMA protocol
    Brix, G
    Zaers, J
    Adam, LE
    Bellemann, ME
    Ostertag, H
    Trojan, H
    Haberkorn, U
    Doll, J
    Oberdorfer, F
    Lorenz, WJ
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (10) : 1614 - 1623
  • [7] Performance evaluation of the whole-body PET scanner ECAT EXACT HR+
    Adam, LE
    Zaers, J
    Ostertag, H
    Trojan, H
    Bellemann, ME
    Brix, G
    Lorenz, WJ
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1270 - 1274
  • [8] Performance evaluation of the new whole-body PET/CT scanner: Discovery ST
    Valentino Bettinardi
    Massimo Danna
    Annarita Savi
    Michela Lecchi
    Isabella Castiglioni
    Maria Carla Gilardi
    Helmut Bammer
    Giovanni Lucignani
    Ferruccio Fazio
    European Journal of Nuclear Medicine and Molecular Imaging, 2004, 31 : 867 - 881
  • [9] Performance evaluation of the new whole-body PET/CT scanner: Discovery ST
    Bettinardi, V
    Danna, M
    Savi, A
    Lecchi, M
    Castiglioni, I
    Gilardi, MC
    Bammer, H
    Lucignani, G
    Fazio, F
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (06) : 867 - 881
  • [10] Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
    Delso, Gaspar
    Furst, Sebastian
    Jakoby, Bjorn
    Ladebeck, Ralf
    Ganter, Carl
    Nekolla, Stephan G.
    Schwaiger, Markus
    Ziegler, Sibylle, I
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 : 238S - 245S