Wavelength Misalignment Analysis and Spectral Calibration for Fourier Domain Polarization-Sensitive Optical Coherence Tomography

被引:1
作者
Chen Yan [1 ,2 ]
Li Zhongliang [1 ,2 ]
Nan Nan [1 ]
Bu Yang [1 ,2 ]
Lu Yu [1 ,2 ]
Song Siyu [1 ,2 ]
Wang Xiangzhao [1 ,2 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Lab Informat Opt & Opt Elect Technol, Shanghai 201800, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
来源
CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG | 2018年 / 45卷 / 02期
关键词
biotechnology; optical coherence tomography; polarization; spectral calibration; error analysis;
D O I
10.3788/CJL201845.0207022
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Fourier domain polarization-sensitive optical coherence tomography (FD-PS-OCT) can measure the polarization properties of a sample to provide early diagnosis for some diseases. The accurate diagnosis is required to measure the polarization parameters in a high accuracy. However, the accuracy is greatly affected by wavelength misalignment. Even a slight wavelength mismatch in FD-PS-OCT will result in nonnegligible polarization artifacts. So an accurate wavelength assignment is necessary. In order to decrease the polarization error and improve the accuracy of spectral calibration, the effect of the wavelength misalignment on the polarization parameters calculation should be clear. An analysis is performed on the relationship between the wavenumber misalignment and the calculated error in theory and simulation. Based on the error analysis, a spectral calibration method is proposed. The method achieves the wavelength alignment through evaluating the retardation and fast axis orientation errors. The wave plate experiments show the good performance of the method and the reasonability of the error analysis.
引用
收藏
页数:9
相关论文
共 21 条
[1]   Single camera based spectral domain polarization sensitive optical coherence tomography [J].
Baumann, Bernhard ;
Goetzinger, Erich ;
Pircher, Michael ;
Hitzenberger, Christoph K. .
OPTICS EXPRESS, 2007, 15 (03) :1054-1063
[2]   Polarization Sensitive Optical Coherence Tomography: A Review of Technology and Applications [J].
Baumann, Bernhard .
APPLIED SCIENCES-BASEL, 2017, 7 (05)
[3]  
CHEN Y, 2014, SPIE, V9230
[4]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[5]   High speed spectral domain polarization sensitive optical coherence tomography of the human retina [J].
Götzinger, E ;
Pircher, M ;
Hitzenberger, CK .
OPTICS EXPRESS, 2005, 13 (25) :10217-10229
[6]  
[贺琪欲 He Qiyu], 2016, [光学学报, Acta Optica Sinica], V36
[7]   POLARIZATION-SENSITIVE LOW-COHERENCE REFLECTOMETER FOR BIREFRINGENCE CHARACTERIZATION AND RANGING [J].
HEE, MR ;
HUANG, D ;
SWANSON, EA ;
FUJIMOTO, JG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1992, 9 (06) :903-908
[8]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[9]   Differential diagnosis of human bladder mucosa pathologies in vivo with cross-polarization optical coherence tomography [J].
Kiseleva, Elena ;
Kirillin, Mikhail ;
Feldchtein, Felix ;
Vitkin, Alex ;
Sergeeva, Ekaterina ;
Zagaynova, Elena ;
Streltzova, Olga ;
Shakhov, Boris ;
Gubarkova, Ekaterina ;
Gladkova, Natalia .
BIOMEDICAL OPTICS EXPRESS, 2015, 6 (04) :1464-1476
[10]   Automated assessment of the remineralization of artificial enamel lesions with polarization-sensitive optical coherence tomography [J].
Lee, Robert C. ;
Kang, Hobin ;
Darling, Cynthia L. ;
Fried, Daniel .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (09) :2950-2962