RECONSTRUCTIVE STRATEGIES FOR RADIOULNAR DISSOCIATION - A BIOMECHANICAL STUDY

被引:66
作者
SELLMAN, DC
SEITZ, WH
POSTAK, PD
GREENWALD, AS
机构
[1] MT SINAI MED CTR,DEPT ORTHOPAED SURG,CLEVELAND,OH 44106
[2] MT SINAI MED CTR,DEPT ORTHOPAED RES,CLEVELAND,OH 44106
关键词
RADIOULNAR DISSOCIATION; FOREARM INTEROSSEOUS MEMBRANE; RADIAL HEAD PROSTHESES;
D O I
10.1097/00005131-199509060-00010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Radial head fracture combined with disruption of the soft-tissue restraints to proximal radial migration is defined as radioulnar dissociation, This injury often involves irreparable radial head fracture. When excised, management has emphasized the use of silicone implants to prevent proximal migration. However, concerns regarding silicone use led to the search for reconstructive alternatives. The purpose of this study was to compare reconstructive methods for radioulnar dissociation, Biomechanical testing to measure radial displacements under physiologic loads was performed on fresh-frozen cadavers after radial head resection. The central interosseous membrane (IOM) was disrupted to simulate radioulnar dissociation. This was followed by an orderly reconstructive sequence including radial head replacement with both silicone and titanium implants as well as a newly described flexible IOM reconstruction, Calculated stiffness values were used for comparison. Silicone implants provided no statistical improvement in forearm stiffness compared with the disrupted membrane state, Significant improvements were achieved with titanium implants and flexible IOM reconstruction, which restored stiffness to 89% and 94% of normal, respectively, No statistical differences were identified between these successful methods. Titanium implants combined with flexible reconstruction increased stiffness to 145% of normal. Further doubt is cast on the role of silicone implants in the management of radioulnar dissociation, Titanium implants and flexible IOM reconstruction appear to be wiser reconstructive choices.
引用
收藏
页码:516 / 522
页数:7
相关论文
共 29 条
[1]  
Cam R.M., Medige J., Curtain D., Koenig A., Silicone rubber replacement of the severely fractured radial head, Clin Or-Thop, 209, pp. 259-269, (1986)
[2]  
Carter P.R., Benton L.J., Dysert P.A., Silicone rubber carpal implants: A study of the incidence of late osseous complications [Abstract], J Hand Surg, 11, pp. 639-644, (1986)
[3]  
Cherry J.C., Use of acrylic prosthesis in the treatment of fracture of the head of the radius, J Bone Joint Surg [Br], 35, pp. 70-71, (1953)
[4]  
Coleman D.A., Blair W.F., Shurr D., Resection of the radial head for fracture of the radial head, J Bone Joint Surg [Am], 69, pp. 385-392, (1987)
[5]  
Curr J.F., Coe W.A., Dislocation of the inferior radio-ulnar joint, Br J Surg, 34, pp. 74-77, (1946)
[6]  
Edwards G.S., Jupiter J.B., Radial head fractures with acute distal radioulnar dislocation. Essex Lopresti revisited, Clin Orthop, 234, pp. 61-69, (1988)
[7]  
Essex-Lopresti P., Fractures of the radial head with distal radio-ulnar dislocation, J Bone Joint Surg [Br], 33, pp. 244-247, (1951)
[8]  
Geel C.W., Palmer A.K., Radial head fractures and their effect on the distal radioulnar joint, Clin Orthop, 275, pp. 79-84, (1992)
[9]  
Goldberg I., Peylan J., Yosipovitch Z., Late results of excision of the radial head for an isolated closed fracture, J Bone Joint Surg [Am], 68, pp. 675-679, (1986)
[10]  
Gordon M., Bullough P.G., Synovial and osseous inflammation in failed silicone-rubber prostheses, J Bone Joint Surg [Am], 64, pp. 574-580, (1982)