This paper provides analytical solutions for the forward conduction and reverse leakage characteristics of junction-barrier-controlled Schottky (JBS) rectifiers. Good agreement between the calculated output characteristics using these solutions and experimental measurements on devices fabricated with different junction depths and Schottky barrier heights is observed. These equations are valuable for the analysis and design of JBC power rectifiers.