PATIENT AND PHYSICIAN ANALYTIC GOALS FOR SELF-MONITORING BLOOD-GLUCOSE INSTRUMENTS

被引:20
|
作者
WEISS, SL
CEMBROWSKI, GS
MAZZE, RS
机构
[1] UNIV MINNESOTA, SCH MED, DEPT PATHOL & LAB MED, PARK NICOLLET MED CTR, MINNEAPOLIS, MN 55416 USA
[2] TUFTS UNIV, SCH MED, BOSTON, MA 02111 USA
[3] UNIV MINNESOTA, SCH MED, DEPT FAMILY PRACTICE, CTR INT DIABET, MINNEAPOLIS, MN 55455 USA
关键词
OFF-SITE TESTING; DIABETES MELLITUS; QUALITY ASSURANCE; BLOOD GLUCOSE; POINT OF CARE TESTING;
D O I
10.1093/ajcp/102.5.611
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The study's objective was to determine the maximum analytical error that is allowable in portable whole blood glucose meters. Interviews were conducted to derive personal reference values and significant deviations from these values for the limit of hypoglycemia, the limit of hyperglycemia, and the upper and lower limits of acceptable blood glucose for physicians and patients with diabetes at the Park Nicollet Medical Center, Minneapolis, Minnesota. Fifty patients with diabetes (30 type I and 20 type II), and 43 physicians (14 endocrinologists, 14 family practitioners, and 15 general internists) were enrolled in the study. The results showed no significant differences between type I and type II diabetic patient responses. Nor were there significant differences among family practitioner, internist, and endocrinologist responses for any of the parameters (the limit of hypoglycemia, the limit of hyperglycemia, the upper and lower limits of acceptable blood glucose for the patient, and the corresponding allowable coefficients of variation at each of these glucose levels). There were significant differences when patients were compared to physicians. Physicians require the highest degree of precision at the limit of hyperglycemia (8.4 +/- 0.28 mmol/L [150.8 +/- 5.1 mg/dl]) with a maximum allowable coefficient of variation (CV) of 7%, a CV significantly lower than that of the patients (CV = 10%). Patients require the highest precision for glucose concentration around the lower acceptable limit (4.7 +/- .013 mmol/L [84.1 +/- 2.5 mg/dL]), with an allowable CV of 8%, a CV significantly lower than that of the physicians (CV = 14%). The authors conclude that the accuracy required by patients and physicians at normal and higher glucose concentrations is achievable by currently available meters. Manufacturers should ascertain that glucose measurements are optimally accurate at glucose levels of 4.7 mmol/L (84.1 mg/dL) and have CVs no higher than 7%.
引用
收藏
页码:611 / 615
页数:5
相关论文
共 50 条
  • [1] THE QUALITY OF SELF-MONITORING OF BLOOD-GLUCOSE
    COLAGIURI, R
    COLAGIURI, S
    JONES, S
    MOSES, RG
    DIABETIC MEDICINE, 1990, 7 (09) : 800 - 804
  • [2] METERS FOR SELF-MONITORING OF BLOOD-GLUCOSE - PRECISION AND CLINICAL USEFULNESS
    REINAUER, KM
    EHMANN, R
    RENN, W
    LOCHER, M
    EGGSTEIN, M
    MEDIZINISCHE WELT, 1991, 42 (05): : 390 - 396
  • [3] Self-monitoring of blood glucose
    不详
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2012, 66 : 2 - 93
  • [4] The dilemma of self-monitoring of blood glucose
    M. B. Davidson
    Diabetologia, 2007, 50 : 497 - 499
  • [5] Overview on self-monitoring of blood glucose
    Montagnana, Martina
    Caputo, Marco
    Giavarina, Davide
    Lippi, Giuseppe
    CLINICA CHIMICA ACTA, 2009, 402 (1-2) : 7 - 13
  • [6] The dilemma of self-monitoring of blood glucose
    Davidson, M. B.
    DIABETOLOGIA, 2007, 50 (03) : 497 - 499
  • [7] Self-monitoring of tear glucose: the development of a tear based glucose sensor as an alternative to self-monitoring of blood glucose
    La Belle, Jeffrey T.
    Adams, Anngela
    Lin, Chi-En
    Engelschall, Erica
    Pratta, Breanna
    Cook, Curtiss B.
    CHEMICAL COMMUNICATIONS, 2016, 52 (59) : 9197 - 9204
  • [8] EVOLUTION OF BLOOD GLUCOSE SELF-MONITORING TECHNOLOGY
    Suplotova, Lyudmila A.
    Alieva, Oksana O.
    DIABETES MELLITUS, 2023, 26 (06): : 566 - 574
  • [9] SELF-MONITORING OF BLOOD-GLUCOSE AND INSULIN DOSE ALTERATION IN TYPE-1 DIABETES-MELLITUS
    ZIEGLER, O
    KOLOPP, M
    LOUIS, J
    MUSSE, JP
    PATRIS, A
    DEBRY, G
    DROUIN, P
    DIABETES RESEARCH AND CLINICAL PRACTICE, 1993, 21 (01) : 51 - 59
  • [10] Accuracy of devices used for self-monitoring of blood glucose
    Johnson, RN
    Baker, JR
    ANNALS OF CLINICAL BIOCHEMISTRY, 1998, 35 : 68 - 74