PULLOUT STRENGTH OF FIXATION SCREWS FROM POLYMETHYLMETHACRYLATE BONE-CEMENT

被引:52
作者
FLAHIFF, CM [1 ]
GOBER, GA [1 ]
NICHOLAS, RW [1 ]
机构
[1] UNIV ARKANSAS MED SCI HOSP,DEPT ORTHOPAED SURG,BIOMECH LAB,LITTLE ROCK,AR 72205
关键词
BONE CEMENT; SCREW FIXATION; PULLOUT STRENGTH;
D O I
10.1016/0142-9612(95)91126-J
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polymethylmethacrylate bone cement is often used to fill voids and increase the strength of osteoporotic and pathological bone. However, it is unclear as to which method of cement augmentation provides optimal screw fixation. This study was conducted to determine which of the current cement augmentation techniques provides the strongest construct when used in association with orthopaedic fixation screws. Pullout strength was determined for screws placed in sawbones with no cement, soft cement, doughy cement and hard cement after drilling and tapping. All cement-screw constructs were significantly stronger than the no cement group. Screws placed in doughy cement had a significantly higher pullout force than those placed in hard cement. Pullout strength of screws placed in soft cement was intermediate between the other cement techniques but not significantly different from either group.
引用
收藏
页码:533 / 536
页数:4
相关论文
共 8 条
[1]   USE OF POLYMETHYLMETHACRYLATE TO ENHANCE SCREW FIXATION IN BONE [J].
CAMERON, HU ;
JACOB, R ;
MACNAB, I ;
PILLIAR, RM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, 57 (05) :655-656
[2]   USE OF METHYLMETHACRYLATE AS AN ADJUNCT IN INTERNAL FIXATION OF MALIGNANT NEOPLASTIC FRACTURES [J].
HARRINGTON, KD ;
JOHNSTON, JO ;
TURNER, RH ;
GREEN, DL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1972, A 54 (08) :1665-1676
[3]   EXPERIMENTAL STABILIZATION OF SEGMENTAL DEFECTS IN HUMAN FEMUR - TORSIONAL STUDY [J].
MENSCH, JS ;
MARKOLF, KL ;
ROBERTS, SB ;
FINERMAN, GM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (02) :185-190
[4]   PULL-OUT STRENGTH OF SCREWS FROM POLYMETHYLMETHACRYLATE CEMENT [J].
MOTZKIN, NE ;
CHAO, EYS ;
AN, KN ;
WIKENHEISER, MA ;
LEWALLEN, DG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (02) :320-323
[5]  
RYAN JR, 1984, CLIN ORTHOPAEDICS, V185, P306
[6]  
SCHATZKER J, 1973, CLIN ORTHOPAEDICS, V108, P115
[7]   ADJUNCTIVE USE OF METHYLMETHACRYLATE IN FIXATION OF PATHOLOGICAL FRACTURES [J].
SIM, FH ;
DAUGHERTY, TW ;
IVINS, JC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (01) :40-48
[8]   HOLDING POWER OF ORTHOPEDIC SCREWS IN EQUINE 3RD METACARPAL AND METATARSAL BONES .1. FOAL BONE [J].
YOVICH, JV ;
TURNER, AS ;
SMITH, FW .
VETERINARY SURGERY, 1985, 14 (03) :221-229