Introduction: Application of dynamic hip screw (DHS) implant for the treatment of unstable intertrochanteric fractures continues to raise concern related to risk of lag screw cut-out with or without subsequent damage to the acetabulum. Measurement of tip-apex distances (TAD) has been recommended to guide the optimal placement of lag screw and to predict subsequent risk of screw cut-out. In this study, the value of TAD was evaluated to verify its usefulness. Methods: This is a retrospective study of 33 consecutive patients with intertrochanteric fracture treated with DHS. Demographic data of the patients were traced from their case notes. Post-operative radiographs were reviewed by focusing on measurement of TAD on anteroposterior and lateral radiographs. Radiographs at one year follow-up were reviewed to depict any fixation-related failure or complication. Results: Fifty two percent of patients did not achieved the recommended TAD of <= 25mm. The mean post-operative TAD was 25.9mm and elderly patients were likely to achieve TAD of <= 25mm. The overall complication rate of 6% was attributed to screw cut-out in two cases. The unstable left-sided fracture was identified to be a potential risk for screw cut-out or migration. Conclusion: TAD is a valuable measurement to guide optimal placement of lag screw during DHS fixation of intertrochanteric fracture.
引用
收藏
页码:31 / 34
页数:4
相关论文
共 50 条
  • [1] Value of Tip-Apex Distance (TAD) in the Fixation of Intertrochanteric Fractures by Dynamic Hip Screw (DHS)
    Khairy, Hossam Mohamed
    El-Alfy, Ali Tawfik
    El-Malt, Ahmed Elsayed
    Samy, Ramy Nabil
    ARCHIVES OF PHARMACY PRACTICE, 2019, 10 (03) : 81 - 86
  • [2] THE VALUE OF THE TIP-APEX DISTANCE IN PREDICTING FAILURE OF FIXATION OF PERITROCHANTERIC FRACTURES OF THE HIP
    BAUMGAERTNER, MR
    CURTIN, SL
    LINDSKOG, DM
    KEGGI, JM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (07): : 1058 - 1064
  • [3] Audit of Tip-Apex Distance in Dynamic Hip Screw Fixation of Proximal Femoral Fractures
    Potter, M.
    Hickey, B.
    BRITISH JOURNAL OF SURGERY, 2024, 111
  • [4] Use of the Tip-Apex Distance in predicting Dynamic Hip Screw Cut Out in Intertrochanteric Fracture of the Femur in Asian Population
    Chua, Y. P.
    Kwan, M. K.
    Ng, W. M.
    Saw, A.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2011, 5 (02) : 24 - 27
  • [5] Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip
    Baumgaertner, MR
    Solberg, BD
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (06): : 969 - 971
  • [6] A Comparison of Tip-Apex Distance at Various Angles of Fixation Devices in Hip Fractures
    Ali, Mohammed
    Al-Dadah, Oday
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [7] Frequency of Lag Screw Cutout After Dynamic Hip Screw Fixation of Stable Intertrochanteric Femur Fracture by Keeping Tip Apex Distance Less Than 25 Milli Meter
    Akhtar, Sajid
    Din, Shahab Ud
    Shah, Faiz Ali
    Mohammad, Wali
    Rehman, Abdur
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2018, 12 (02): : 842 - 844
  • [8] Measurement of Tip Apex Distance and Migration of Lag Screws and Novel Blade Screw Used for the Fixation of Intertrochanteric Fractures
    Yang, Jesse Chieh-Szu
    Chen, Hsin-Chang
    Lai, Yu-Shu
    Cheng, Cheng-Kung
    PLOS ONE, 2017, 12 (01):
  • [9] SYSTEMATIC REVIEW OF TIP APEX DISTANCE (TAD) IN DYNAMIC HIP SCREW (DHS) FIXATION OF OSTEOPOROTIC HIP FRACTURES
    Abdulkareem, Imran Haruna
    OSTEOPOROSIS INTERNATIONAL, 2012, 23 : S606 - S607
  • [10] Screw fracture after sliding hip screw fixation of an intertrochanteric fracture
    Manicom, O.
    Karoubi, M.
    Mseddi, M.
    Demoura, A.
    Hernigou, P.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2006, 92 (06): : 602 - 605