THE INFLUENCE OF FIXATION PEG DESIGN ON THE SHEAR STABILITY OF PROSTHETIC IMPLANTS

被引:22
作者
GIORI, NJ [1 ]
BEAUPRE, GS [1 ]
CARTER, DR [1 ]
机构
[1] STANFORD UNIV, DEPT MECH ENGN, DIV DESIGN, STANFORD, CA 94305 USA
关键词
Fixation peg; Implant stability; Initial fixation; Prosthesis design; Shear fixation;
D O I
10.1002/jor.1100080615
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The variety of fixation peg designs existing on prosthetic implants indicates uncertainty regarding the optimum design of fixation pegs for the reduction of stress and relative motion at the bone‐implant interface. Fixation pegs have a number of important functions on a prosthesis, one of which is to reduce shear stress and shear displacement at the bone‐implant interface. This is a parametric study intended to identify trends in the shear stability of prostheses incorporating a range of fixation peg designs. The parameters varied included the number of fixation pegs on a surface, the size of the pegs, and the aspect ratio (length/diameter) of the pegs. Mechanical tests were performed on urethane foam blocks with mechanical properties comparable to trabecular bone. The results indicated the following: (a) Fixation pegs act independently in resisting shearing force if they are spaced sufficiently far apart. (b) For any given shear displacement, smaller pegs generate a greater resistive shear force per unit of peg projected area in the direction of the applied load than larger pegs having the same aspect ratio. (c) Smaller diameter pegs cause the supporting material to yield at lower displacements. (d) Pegs with a high aspect ratio provide high shear stability with a minimum amount of bone removed, but may bend if the aspect ratio becomes excessive. (e) Smaller, slender pegs generate a greater resistive shear force at a given displacement per unit of peg volume than larger, lower aspect ratio pegs. The results of this study suggest that it may be possible to design prostheses with multiple smaller fixation pegs that conserve bone stock, distribute stress more uniformly to the supporting bone, and have stronger and stiffer shear fixation than prostheses with fewer larger pegs. Copyright © 1990 Orthopaedic Research Society
引用
收藏
页码:892 / 898
页数:7
相关论文
共 19 条
[1]   FAILURE OF THE METAL-BACKED PATELLAR COMPONENT AFTER TOTAL KNEE REPLACEMENT [J].
BAYLEY, JC ;
SCOTT, RD ;
EWALD, FC ;
HOLMES, GB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (05) :668-674
[2]  
BOBYN JD, 1982, CLIN ORTHOP RELAT R, P301
[3]  
BOURNE RB, 1986, CLIN ORTHOP RELAT R, P95
[4]   COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :954-962
[5]   STRESS CHANGES IN THE FEMORAL-HEAD DUE TO POROUS INGROWTH SURFACE REPLACEMENT ARTHROPLASTY [J].
CARTER, DR ;
VASU, R ;
HARRIS, WH .
JOURNAL OF BIOMECHANICS, 1984, 17 (10) :737-&
[6]   STRESS-ANALYSIS OF A CONDYLAR KNEE TIBIAL COMPONENT - INFLUENCE OF METAPHYSEAL SHELL PROPERTIES AND CEMENT INJECTION DEPTH [J].
CHEAL, EJ ;
HAYES, WC ;
LEE, CH ;
SNYDER, BD ;
MILLER, J .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1985, 3 (04) :424-434
[7]   THE INFLUENCE OF TIBIAL-PATELLOFEMORAL LOCATION ON FUNCTION OF THE KNEE IN PATIENTS WITH THE POSTERIOR STABILIZED CONDYLAR KNEE PROSTHESIS [J].
FIGGIE, HE ;
GOLDBERG, VM ;
HEIPLE, KG ;
MOLLER, HS ;
GORDON, NH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1035-1040
[8]   TOTAL ELBOW ARTHROPLASTY [J].
GOLDBERG, VM ;
FIGGIE, HE ;
INGLIS, AE ;
FIGGIE, MP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (05) :778-783
[9]  
HEDLEY AK, 1982, CLIN ORTHOP RELAT R, P300
[10]  
INSALL JN, 1988, CLIN ORTHOP RELAT R, P43