A MICROCOMPUTER SYSTEM FOR ASSESSMENT OF PERIPHERAL-BLOOD FLOW - AN EXAMPLE OF NASAL BLOOD-FLOW

被引:0
|
作者
GRONFORS, T
PYYKKO, I
AALTO, H
JUHOLA, M
ISHIZAKI, H
机构
[1] INST OCCUPAT HLTH, SF-06120 VANTAA 62, FINLAND
[2] UNIV HELSINKI, DEPT OTOLARYNGOL, SF-00100 HELSINKI 10, FINLAND
关键词
CHRONIC RHINITIS; IONTOPHORETIC METHOD; LASER DOPPLER FLOWMETER; MICROCOMPUTER; PATTERN RECOGNITION;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have designed and implemented a microcomputer system for studying the effect of various mediator substances on the nasal blood flow. The system uses an IBM PC/AT microcomputer, which is connected with a Laser Doppler Flowmeter (LDF) and an iontophoretic drug application system. The LDF measures flux from the tissue that in the example is the inferior nasal turbinate. The flux is converted to digital form by an analog-digital converter of 12 bits. The program is implemented in the Pascal language. In the analysis, a flux level, amplitude, rise time and decay time of the pulse wave are determined. The effect of drugs on the flux can be studied by applying them iontophoretically. In the program the length and number of the drug application periods as well as the recording period are user-driven. In the nasal blood flow iontophoretically administered adrenaline reduced significantly the flux parameters and histamine canceled this effect. Tachyphylaxis was a frequent observation in repeated measurements. The system can be used to evaluate the role of different transmitters in the etiology of chronic rhinitis.
引用
收藏
页码:119 / 128
页数:10
相关论文
共 50 条
  • [1] PERIPHERAL-BLOOD FLOW STUDIES USING BLOOD-FLOW MONITOR SYSTEM 8
    HELINSKI, HJ
    GOODEN, DS
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (03): : 454 - &
  • [2] NASAL BLOOD-FLOW
    DRUCE, HM
    ANNALS OF ALLERGY, 1993, 71 (03): : 288 - 291
  • [3] BLOOD-FLOW IN THE PERIPHERAL VESTIBULAR SYSTEM
    ANGELBORG, C
    LARSEN, HC
    JOURNAL OF OTOLARYNGOLOGY, 1985, 14 (01): : 41 - 43
  • [4] A MICROCOMPUTER SYSTEM FOR MEASUREMENT OF CORONARY BLOOD-FLOW IN MAN
    CULLING, W
    FLORES, NA
    SHERIDAN, DJ
    THOMAS, P
    JOURNAL OF PHYSIOLOGY-LONDON, 1986, 374 : P14 - P14
  • [5] BLOOD-FLOW IN NASAL POLYPS
    BENDE, M
    FLISBERG, K
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1985, 99 (02): : 167 - 169
  • [6] PERIPHERAL-BLOOD FLOW IN THE NEONATE - CHANGES IN TOTAL, SKIN AND MUSCLE BLOOD-FLOW WITH GESTATIONAL AND POSTNATAL AGE
    WU, PYK
    WONG, W
    GUERRA, G
    MIRANDA, R
    GODOY, R
    PRESTON, B
    SCHOENTGEN, S
    LEVAN, N
    CLINICAL RESEARCH, 1980, 28 (01): : A128 - A128
  • [7] CIRCULATORY INSUFFICIENCIES AND PERIPHERAL-BLOOD FLOW .1. STUDY ON CUTANEOUS BLOOD-FLOW WITH ELECTRONIC PLETHYSMOGRAPHY
    WAREMBOURG, H
    LEKIEFFRE, J
    GENTIT, F
    CARRE, A
    DUPUIS, B
    LILLE MEDICAL, 1972, 17 (01): : 58 - +
  • [8] ASSESSMENT OF PERIPHERAL-BLOOD FLOW USING A PULSE OXIMETER
    VEGFORS, M
    TRYGGVASON, B
    SJOBERG, F
    LENNMARKEN, C
    JOURNAL OF CLINICAL MONITORING, 1990, 6 (01): : 1 - 4
  • [9] NASAL BLOOD-FLOW RESPONSES TO NASAL PROVOCATION
    DRUCE, H
    PATOW, C
    BONNER, R
    CHOO, P
    SUMMERS, R
    KALINER, M
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1983, 71 (01) : 90 - 90
  • [10] CIRCULATORY INSUFFICIENCIES AND PERIPHERAL-BLOOD FLOW .2. STUDY ON MUSCULAR BLOOD-FLOW BY XENON-133
    WAREMBOURG, H
    SWYNGEDAUW, J
    DUPUIS, B
    LEKIEFFRE, J
    HUART, M
    LILLE MEDICAL, 1972, 17 (01): : 63 - +