Reliability and validity of the Infoot 3D foot digitizer for normal healthy adults

被引:21
作者
De Mits, Sophie [1 ,2 ]
Coorevits, Pascal [3 ,4 ]
De Clercq, Dirk [5 ]
Elewaut, Dirk [6 ]
Woodburn, Jim [7 ]
Roosen, Philip [1 ,2 ]
机构
[1] Univ Ghent, B-9000 Ghent, Belgium
[2] Artevelde Univ Coll, Rehabil Sci & Phys Therapy, B-9000 Ghent, Belgium
[3] Univ Ghent, Dept Publ Hlth, Ghent, Belgium
[4] Univ Ghent, RAMIT Vzw, Ghent, Belgium
[5] Univ Ghent, Movement & Sport Sci, Ghent, Belgium
[6] Ghent Univ Hosp, Dept Rheumatol, Ghent, Belgium
[7] Glasgow Caledonian Univ, Sch Hlth & Social Care & HealthQWest, Glasgow, Lanark, Scotland
关键词
foot digitizer; 3D scanning; foot morphology; foot deformity; validity; reliability;
D O I
10.1080/19424281003685694
中图分类号
TB18 [人体工程学];
学科分类号
1201 ;
摘要
Introduction: Abnormal foot posture and foot deformities have been identified as important factors in several foot and lower limb dysfunctions and pathologies. There is still no consensus over the optimum technique( s) to quantify these; hence a foot digitizer might be used as an objective measurement tool. The objective of this study is to check for the validity and the reliability of the Infoot digitizer. Methods: To investigate the validity of the Infoot digitizer in comparison with weight bearing X-rays and clinical measurements, both used in daily clinical practice, Pearson correlation coefficients were calculated and Bland-Altman plots were analysed. To investigate the reliability of the Infoot digitizer ICC, SEM, SDD and SDD% were calculated. Results and conclusions: Within this healthy population good validity could be demonstrated comparing the linear measurements from the Infoot 3D foot digitizer with the data from X-rays and clinical measurements. The majority of the obtained parameters proved to be very reliable.
引用
收藏
页码:65 / 75
页数:11
相关论文
共 37 条
[1]  
Anastasi A, 1988, PSYCHOL TESTING
[2]  
Angst F, 2001, ARTHRIT RHEUM-ARTHR, V45, P384, DOI 10.1002/1529-0131(200108)45:4<384::AID-ART352>3.0.CO
[3]  
2-0
[4]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[5]  
BUDIMANMAK E, 1994, J RHEUMATOL, V21, P623
[6]  
Cavanagh PR, 2000, DIABETES-METAB RES, V16, pS6, DOI 10.1002/1520-7560(200009/10)16:1+<::AID-DMRR130>3.0.CO
[7]  
2-Z
[8]  
Chan Y H, 2003, Singapore Med J, V44, P614
[9]   Measurement of forefoot varus angle by laser technology in people with flexible flatfoot [J].
Chen, MJL ;
Chen, CPC ;
Lew, HL ;
Hsieh, WC ;
Yang, WP ;
Tang, SFT .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2003, 82 (11) :842-846
[10]   Test-retest reliability of wavelet - and Fourier based EMG (instantaneous) median frequencies in the evaluation of back and hip muscle fatigue during isometric back extensions [J].
Coorevits, Pascal ;
Danneels, Lieven ;
Cambier, Dirk ;
Ramon, Herman ;
Druyts, Hans ;
Karlsson, J. Stefan ;
De Moor, Georges ;
Vanderstraeten, Guy .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2008, 18 (05) :798-806