CIRCADIAN VARIATION OF VENTRICULAR ARRHYTHMIA RECURRENCES AFTER CARDIOVERTER-DEFIBRILLATOR IMPLANTATION IN PATIENTS WITH HEALED MYOCARDIAL INFARCTS

被引:25
作者
MALLAVARAPU, C [1 ]
PANCHOLY, S [1 ]
SCHWARTZMAN, D [1 ]
CALLANS, DJ [1 ]
HEO, JY [1 ]
GOTTLIEB, CD [1 ]
MARCHLINSKI, FE [1 ]
机构
[1] PRESBYTERIAN MED CTR,PHILADELPHIA HEART INST,CLIN ELECTROPHYSIOL LAB,PHILADELPHIA,PA 19104
关键词
D O I
10.1016/S0002-9149(99)80746-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Past studies using Holter monitoring and retrospective reviews of death certificates have documented peak occurrence of sudden death and nonsustained ventricular tachycardia (Vr) in the morning hours, We used the Ventritex CadenceTM device (Ventritex, Sunnyvale, California) which documents the date and time of all stored arrhythmias leading to device therapy to evaluate the circadian pattern of sustained ventricular arrhythmia recurrence. Mean follow-up after defibrillator implantation was 628 +/- 285 days. All 390 patients had at least 1 episode (range 1 to 43) of sustained VT documented from analysis of the stored electrograms associated with an arrhythmia event. Stored electrograms were available for review and analysis in 3,041 device detections; 349 stored events were excluded because they did not fulfill the diagnostic criteria for VT or failed to document the onset of the ventricular arrhythmia at the beginning of the recorded event of the arrhythmia episode. Criteria for the diagnosis of VT or ventricular fibrillation were met in 2,692 arrhythmia episodes occurring in 390 patients. There was circadian variation for ventricular arrhythmia recurrence for the whole patient group with the data fit to the sinusoidal density function: f(t) = 126 - 51 x cos (-57 + 2 pi t/24) - 25 x sin (63 + 2 pi t/12) (p <0.0001). Ventricular arrhythmia occurrence rate was lowest between 2:00 and 3:00 A.M., and highest between 10:00 and 11:00 A.M. In addition, the same circadian pattern was demonstrated regardless of patient age, gender, left ventricular ejection fraction (<35% or greater than or equal to 35%), and VT cycle length (<300 or greater than or equal to 300 ms). There is a definite circadian distribution of ventricular arrhythmia occurrence in patients with implantable cardioverter-defibrillators. The circadian pattern is similar regardless of the patients' age, gender, election fraction, or VT cycle length.
引用
收藏
页码:1140 / 1144
页数:5
相关论文
共 21 条
[1]   CIRCADIAN VARIATION OF PRIMARY CARDIAC-ARREST OR SUDDEN CARDIAC DEATH IN PATIENTS AGED 62 TO 100 YEARS (MEAN 82) [J].
ARONOW, WS ;
AHN, C .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (16) :1455-1456
[2]   USE OF BIPOLAR RECORDINGS FROM PATCH-PATCH AND RATE SENSING LEADS TO DISTINGUISH VENTRICULAR-TACHYCARDIA FROM SUPRAVENTRICULAR RHYTHMS IN PATIENTS WITH IMPLANTABLE CARDIOVERTER DEFIBRILLATORS [J].
CALLANS, DJ ;
HOOK, BG ;
MARCHLINSKI, FE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11) :1917-1922
[3]   UNIQUE SENSING ERRORS IN 3RD-GENERATION IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS [J].
CALLANS, DJ ;
HOOK, BG ;
KLEIMAN, RB ;
MITRA, RL ;
FLORES, BT ;
MARCHLINSKI, FE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (04) :1135-1140
[4]   CIRCADIAN DISTRIBUTION IN FATAL PULMONARY THROMBOEMBOLISM [J].
COLANTONIO, D ;
CASALE, R ;
ABRUZZO, BP ;
LORENZETTI, G ;
PASQUALETTI, P .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (05) :403-404
[5]  
HOOK BG, 1991, J AM COLL CARDIOL, V17, P985
[6]   IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR THERAPY IN THE ABSENCE OF SIGNIFICANT SYMPTOMS - RHYTHM DIAGNOSIS AND MANAGEMENT AIDED BY STORED ELECTROGRAM ANALYSIS [J].
HOOK, BG ;
CALLANS, DJ ;
KLEIMAN, RB ;
FLORES, BT ;
MARCHLINSKI, FE .
CIRCULATION, 1993, 87 (06) :1897-1906
[7]   CIRCADIAN OCCURRENCE OF SYMPTOMATIC PAROXYSMAL SUPRAVENTRICULAR TACHYCARDIA IN UNTREATED PATIENTS [J].
IRWIN, JM ;
MCCARTHY, EA ;
WILKINSON, WE ;
PRITCHETT, ELC .
CIRCULATION, 1988, 77 (02) :298-300
[8]   CIRCADIAN VARIATION OF SUSTAINED VENTRICULAR-TACHYCARDIA IN PATIENTS WITH CORONARY-ARTERY DISEASE AND IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS [J].
LAMPERT, R ;
ROSENFELD, L ;
BATSFORD, W ;
LEE, F ;
MCPHERSON, C .
CIRCULATION, 1994, 90 (01) :241-247
[9]   CIRCADIAN VARIATION OF VENTRICULAR-TACHYCARDIA IN ACUTE MYOCARDIAL-INFARCTION [J].
LUCENTE, M ;
REBUZZI, AG ;
LANZA, GA ;
TAMBURI, S ;
CORTELLESSA, MC ;
COPPOLA, E ;
IANNARELLI, M ;
MANZOLI, U .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (10) :670-674
[10]   CIRCADIAN VARIATION IN THE FREQUENCY OF SUDDEN CARDIAC DEATH [J].
MULLER, JE ;
LUDMER, PL ;
WILLICH, SN ;
TOFLER, GH ;
AYLMER, G ;
KLANGOS, I ;
STONE, PH .
CIRCULATION, 1987, 75 (01) :131-138