Endothelial cell counts after Descemet's stripping automated endothelial keratoplasty versus penetrating keratoplasty in Asian eyes

被引:26
作者
Ang, Marcus [1 ,2 ]
Mehta, Jodhbir S. [1 ,2 ,3 ,4 ]
Anshu, Arundhati [1 ,2 ]
Wong, Hon Kiat [5 ]
Htoon, Hla M. [2 ]
Tan, Donald [1 ,2 ,3 ]
机构
[1] Singapore Natl Eye Ctr, 11 Third Hosp Ave, Singapore 168751, Singapore
[2] Singapore Eye Res Inst, Singapore, Singapore
[3] Natl Univ Hlth Syst, Dept Ophthalmol, Singapore, Singapore
[4] Duke NUS Grad Med Sch, Dept Clin Sci, Singapore, Singapore
[5] Tan Tock Seng Hosp, Dept Ophthalmol, Singapore, Singapore
关键词
Descemet's stripping automated endothelial keratoplasty; endothelial cell count; penetrating keratoplasty;
D O I
10.2147/OPTH.S26343
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The purpose of this study was to compare endothelial cell counts after Descemet's stripping automated endothelial keratoplasty (DSAEK) and penetrating keratoplasty in Asian eyes. Methods: This was a retrospective study of patients from our prospective Singapore Corneal Transplant Study cohort who received corneal transplantation in 2006-2008. We compared eyes that underwent DSAEK or penetrating keratoplasty for Fuchs' endothelial dystrophy or pseudophakic and aphakic bullous keratopathy. Clinical data, and donor and recipient characteristics were recorded. Of 241 patients who met our inclusion criteria, 68 underwent DSAEK and 173 underwent penetrating keratoplasty. The main outcome measure was endothelial cell loss at 1 year. Secondary outcome measures were graft survival and visual outcomes at 1-year follow-up. Results: There were no significant differences in baseline characteristics of patients between the treatment groups. Percent endothelial cell loss at 1-year follow-up was greater in penetrating keratoplasty eyes (40.9% +/- 2.9%) compared with DSAEK eyes (22.4% +/- 2.3%; P < 0.001). DSAEK-treated eyes had significantly superior uncorrected visual acuity (mean difference = 0.42 +/- 0.0059; P < 0.001) and best spectacle-corrected visual acuity (mean difference = 0.14 +/- 0.032; P < 0.001) as compared with penetrating keratoplasty-treated eyes. Penetrating keratoplasty-treated eyes had worse astigmatism as compared with DSAEK-treated eyes (-3.0 +/- 2.1 versus -1.7 +/- 0.8; P < 0.001). Graft survival at 1 year was comparable in both groups, ie, 66/68 (97.0%) DSAEK-treated eyes versus 158/173 (92.0%) of penetrating keratoplasty-treated eyes had clear grafts (P = 0.479). Conclusion: We report lower percent endothelial cell loss comparing DSAEK and penetrating keratoplasty at 1-year follow-up in Asian eyes, with comparable graft survival rates in both groups.
引用
收藏
页码:537 / 544
页数:8
相关论文
共 26 条
[1]   Prediction of visual outcome after penetrating keratoplasty for pseudophakic corneal edema [J].
Barkana, Y ;
Segal, O ;
Krakovski, D ;
Avni, I ;
Zadok, D .
OPHTHALMOLOGY, 2003, 110 (02) :286-290
[2]   Penetrating keratoplasty: outcomes from a corneal unit compared to national data [J].
Beckingsale, P. ;
Mavrikakis, I. ;
Al-Yousuf, N. ;
Mavrikakis, E. ;
Daya, S. M. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (06) :728-731
[3]   A modified technique for Descemet membrane stripping automated endothelial keratoplasty to minimize endothelial cell loss [J].
Busin, Massimo ;
Bhatt, Priya R. ;
Scorcia, Vincenzo .
ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (08) :1133-1137
[4]   Busin Glide vs Forceps in Descemet Stripping Automated Endothelial Keratoplasty: Not All Forceps Insertions are Created Equal [J].
Chen, Edwin S. ;
Shamie, Neda ;
Terry, Mark A. ;
Phillips, Paul M. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (01) :175-175
[5]   Comparison of Outcomes of Lamellar Keratoplasty and Penetrating Keratoplasty in Keratoconus [J].
Han, Daphne C. Y. ;
Mehta, Jodhbir S. ;
Por, Yong Ming ;
Htoon, Hla Myint ;
Tan, Donald T. H. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (05) :744-751
[6]   Descemet's stripping automated endothelial keratoplasty and penetrating keratoplasty for Fuchs' endothelial dystrophy [J].
Hjortdal, Jesper ;
Ehlers, Niels .
ACTA OPHTHALMOLOGICA, 2009, 87 (03) :310-314
[7]   Visual acuity measurements [J].
Holladay, JT .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (02) :287-290
[8]   Descemet Stripping Automated Endothelial Keratoplasty With a Graft Insertion Device: Surgical Technique and Early Clinical Results [J].
Khor, Wei-Boon ;
Mehta, Jodhbir S. ;
Tan, Donald Tiang-Hwee .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (02) :223-232
[9]   Descemet's Stripping Endothelial Keratoplasty: Safety and Outcomes A Report by the American Academy of Ophthalmology [J].
Lee, W. Barry ;
Jacobs, Deborah S. ;
Musch, David C. ;
Kaufman, Stephen C. ;
Reinhart, William J. ;
Shtein, Roni M. .
OPHTHALMOLOGY, 2009, 116 (09) :1818-1830
[10]   Penetrating keratoplasty for keratoconus: Visual outcome and success [J].
Lim, L ;
Pesudovs, K ;
Coster, DJ .
OPHTHALMOLOGY, 2000, 107 (06) :1125-1131