CHARACTERISTICS OF THE UMBILICAL ARTERY VELOCITY WAVE-FORM AS FUNCTION OF MEASUREMENT SITE

被引:7
|
作者
RUISSEN, CJ [1 ]
VONDRONGELEN, MMHP [1 ]
HOOGLAND, HJ [1 ]
JAGER, W [1 ]
HOEKS, APG [1 ]
机构
[1] STATE UNIV LIMBURG,DEPT OBSTET & GYNECOL,6200 MD MAASTRICHT,NETHERLANDS
关键词
PULSATILITY INDEX; FLOW VELOCITY WAVE-FORM; FREQUENCY DISTRIBUTION INDEX; MEASUREMENT SITE; UMBILICAL ARTERY; VELOCITY PROFILE;
D O I
10.1159/000293272
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
In 30 uncomplicated singleton pregnancies, varying in duration between 24 and 40 weeks, the variability of the flow velocity waveform (FVW) along the course of the umbilical artery was investigated. Blood flow velocities were recorded at 4 locations in the vessel: within the fetal abdomen, 0-5 cm from the origin of the umbilical cord, in the free-floating part, and 0-5 cm from its insertion in the placenta. From the Doppler signals recorded, the pulsatility index (PI) and a parameter for the frequency distribution index (FDI) were calculated. PI values differed among the locations, but no unequivocal tendency could be demonstrated. Statistical analysis, including multiiple regression analysis for maternal and menstrual age and fetal heart rate, showed no significant difference in PI and FDI values for any of the 4 locations. It can be concluded that in uncomplicated pregnancies, possible changes in FVW (quantified by PI) along the course of the umbilical artery have no clinical relevance. Therefore, standardization for the sampling site when measuring PI in this vessel seems to be unnecessary.
引用
收藏
页码:212 / 216
页数:5
相关论文
共 50 条
  • [41] A COMPARISON OF DOPPLER ULTRASOUND WAVE-FORM INDEXES IN THE UMBILICAL ARTERY .2. INDEXES DERIVED FROM THE MEAN VELOCITY AND 1ST MOMENT WAVE-FORMS
    THOMPSON, RS
    TRUDINGER, BJ
    COOK, CM
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (11): : 845 - 854
  • [42] WAVE-FORM PATTERN-RECOGNITION - A NEW SEMIQUANTITATIVE METHOD FOR ANALYSIS OF FETAL AORTIC AND UMBILICAL ARTERY BLOOD-FLOW VELOCITY RECORDED BY DOPPLER ULTRASOUND
    MALCUS, P
    ANDERSSON, J
    MARSAL, K
    OLOFSSON, PA
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (05): : 453 - 460
  • [43] SPECTRAL AND WAVE-FORM CHARACTERISTICS OF FINE AND COARSE CRACKLES
    MUNAKATA, M
    UKITA, H
    DOI, I
    OHTSUKA, Y
    MASAKI, Y
    HOMMA, Y
    KAWAKAMI, Y
    THORAX, 1991, 46 (09) : 651 - 657
  • [44] AN INVESTIGATION OF SIMULATED UMBILICAL ARTERY DOPPLER WAVE-FORMS .2. A COMPARISON OF 3 DOPPLER WAVE-FORM QUALITY INDEXES
    HOSKINS, PR
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (01): : 23 - 30
  • [45] CORONARY-ARTERY FLOW VELOCITY WAVE-FORM IN ACUTE MYOCARDIAL-INFARCTION WITH ANGIOGRAPHIC NO-REFLOW
    NEMOTO, T
    KIMURA, K
    SHIMIZU, T
    MOCHIDA, Y
    KOSUGE, M
    KUJI, N
    ISHIKAWA, T
    MIYAZAKI, N
    TOCHIKUBO, O
    ISHII, M
    CIRCULATION, 1995, 92 (08) : 1545 - 1545
  • [46] UMBILICAL VENOUS DOPPLER WAVE-FORM WITHOUT FETAL BREATHING - ITS SIGNIFICANCE
    MITRA, SC
    AMERICAN JOURNAL OF PERINATOLOGY, 1995, 12 (03) : 217 - 219
  • [47] MATERNAL RENAL-ARTERY DOPPLER FLOW-VELOCITY WAVE-FORM IN PREECLAMPSIA - A PRELIMINARY-REPORT
    KUO, DM
    CHIU, TH
    HSIEH, TT
    JOURNAL OF REPRODUCTIVE MEDICINE, 1993, 38 (03) : 189 - 192
  • [48] DOPPLER FLOW VELOCITY WAVE-FORM ANALYSIS PREDICTING PRETERM BIRTH
    JORN, H
    FUNK, A
    FENDEL, H
    ZEITSCHRIFT FUR GEBURTSHILFE UND PERINATOLOGIE, 1993, 197 (05): : 225 - 230
  • [49] A SYSTEM FOR RAPID ANALYSIS OF THE FEMORAL BLOOD VELOCITY WAVE-FORM AT THE BEDSIDE
    CAPPER, WL
    AMOORE, JN
    CLIFFORD, PC
    IMMELMAN, EJ
    HARRIESJONES, EP
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (01): : 31 - 38
  • [50] DIRECT MEASUREMENT OF THE SWITCHING WAVE-FORM IN A DC-SQUID
    FUJIMAKI, A
    NAKAJIMA, K
    SAWADA, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1987, 26 (01): : 74 - 80