Determination of total nonstructural carbohydrates in tree species by high-performance anion-exchange chromatography with pulsed amperometric detection

被引:37
|
作者
Wilson, R
Cataldo, A
Andersen, CP
机构
[1] US EPA, ENVIRONM RES LAB, CORVALLIS, OR 97333 USA
[2] MANTECH ENVIRONM TECHNOL INC, CORVALLIS, OR 97333 USA
关键词
D O I
10.1139/x95-218
中图分类号
S7 [林业];
学科分类号
0829 ; 0907 ;
摘要
Tracing shifts in carbohydrate pools has become an important tool for studying the integration of plant responses to natural and anthropogenic stresses on tree species. As a result, the need for a rapid and sensitive analytical technique to measure the components in the total nonstructural carbohydrate pool in various plant tissues has increased. In this paper we report carbohydrate data for five species that were obtained using a high-performance anion-exchange chromatography method that uses an alkaline, isocratic mobile phase (160 mM NaOH) with triple-pulsed amperometric detection. This approach has been applied to the analysis of sugar alcohols, monosaccharides, disaccharides, and other oligosaccharides in ponderosa pine (Pinus ponderosa Dougl. ex Laws.), black cherry (Prunus serotina Ehrh.), and other species roots, branches, stems, and needles. The results show the range of tissue concentrations found and suggest the usefulness of the anion-exchange method for the routine quantification of the total nonstructural carbohydrate pool in trees with minimal sample preparation and cleanup. Base-line resolution of the soluble carbohydrates was accomplished in less than 13 min. The chromatographic analysis of starch as glucose was complete in less than 4 min. Electrochemical detection enabled selectivity of the carbohydrates and higher sensitivity over the conventional colorimetric assays or high-performance liquid chromatography with refractive index detection. The minimum levels of quantification were 4.5 ng for myo-inositol, 4.6 ng for sorbitol, 4.5 ng for glucose and fructose, 17.1 ng for sucrose, and 29.7 ng for raffinose.
引用
收藏
页码:2022 / 2028
页数:7
相关论文
共 50 条
  • [1] DETERMINATION OF CARBOHYDRATES BY ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION
    ROCKLIN, RD
    POHL, CA
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1983, 6 (09): : 1577 - 1590
  • [2] HIGH-PERFORMANCE ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION OF NUTRITIONALLY SIGNIFICANT CARBOHYDRATES
    CORRADINI, C
    CRISTALLI, A
    CORRADINI, D
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (16): : 3471 - 3485
  • [3] DETERMINATION OF AMINOSACCHARIDES BY HIGH-PERFORMANCE ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION
    MARTENS, DA
    FRANKENBERGER, WT
    TALANTA, 1991, 38 (03) : 245 - 251
  • [4] DETERMINATION OF SACCHARIDES BY HIGH-PERFORMANCE ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION
    MARTENS, DA
    FRANKENBERGER, WT
    CHROMATOGRAPHIA, 1990, 29 (1-2) : 7 - 12
  • [5] Analysis of nonstructural carbohydrates in storage organs of 30 ornamental geophytes by high-performance anion-exchange chromatography with pulsed amperometric detection
    Ranwala, Anil P.
    Miller, William B.
    NEW PHYTOLOGIST, 2008, 180 (02) : 421 - 433
  • [6] HIGH-PERFORMANCE ANION-EXCHANGE CHROMATOGRAPHY OF CARBOHYDRATES USING A NEW RESIN AND PULSED AMPEROMETRIC DETECTION
    CORRADINI, C
    CORRADINI, D
    HUBER, CG
    BONN, GK
    CHROMATOGRAPHIA, 1995, 41 (9-10) : 511 - 515
  • [7] DETERMINATION OF CARBOHYDRATES IN WOOD, PULP AND PROCESS LIQUOR SAMPLES BY HIGH-PERFORMANCE ANION-EXCHANGE CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION
    SULLIVAN, J
    DOUEK, M
    JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) : 339 - 350
  • [8] Determination of sugar phosphates by high-performance anion-exchange chromatography coupled with pulsed amperometric detection
    Jeong, Ji-Seon
    Kwon, Ha-Jeong
    Lee, Yong-Moon
    Yoon, Hye-Ran
    Hong, Seon-Pyo
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1164 (1-2) : 167 - 173
  • [9] Determination of several sugars in serum by high-performance anion-exchange chromatography with pulsed amperometric detection
    Cai, YQ
    Liu, JS
    Shi, YL
    Liang, LN
    Mou, SF
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1085 (01) : 98 - 103
  • [10] Simultaneous determination of 13 carbohydrates using high-performance anion-exchange chromatography coupled with pulsed amperometric detection and mass spectrometry
    Zhao, Dan
    Feng, Feng
    Yuan, Fei
    Su, Jin
    Cheng, Yan
    Wu, Hanqiu
    Song, Kun
    Nie, Bo
    Yu, Lian
    Zhang, Feng
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (08) : 1843 - 1854