THE USE OF XE-133 FOR MEASUREMENT OF BLOOD-FLOW THROUGH SYSTEMIC ARTERIOVENOUS-MALFORMATIONS BEFORE AND AFTER THERAPEUTIC EMBOLIZATION

被引:0
作者
KENNEDY, AM
BANKS, LM
MACSWEENEY, JE
MYERS, MJ
PETERS, AM
ALLISON, DJ
机构
[1] HAMMERSMITH HOSP,DEPT DIAGNOST RADIOL,LONDON W12 0HS,ENGLAND
[2] HAMMERSMITH HOSP,DEPT MED PHYS,LONDON W12 0HS,ENGLAND
关键词
D O I
10.1259/0007-1285-68-812-844
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Embolization is increasingly used to treat systemic arteriovenous (AV) shunts although its success, as judged by either angiographic or clinical means, is difficult to quantify. The aim of the study was to quantify blood flow through AV shunts with Xe-133, which, because of its relatively long transit time through peripheral tissues, behaves like microspheres. Following arterial injection, Xe-133 entering an AV shunt rapidly arrives in the lung and can be quantified with a scintillation probe. In 17 patients with systemic AV shunts, the reduction in shunt flow following therapeutic embolization was quantified in the angiography theatre by comparing the initial count rates in the lung, recorded by probe, following injection of identical quantities of Xe-133 into a supplying artery before and after embolization. By comparing the lung counts with those given by an intravenous injection of Xe-133, the fraction of flow at the catheter tip entering the shunt was also quantified. Tissue perfusion in the vascular territory distal to the shunt was measured at the same time by recording the clearance of non-shunted Xe-133 with a second probe over the extremity. Control injections of Xe-133 were given in the contralateral limb in order to assess Xe-133 transit in the absence of shunting and to compare tissue perfusion between the two sides. Shunt flow ranged from 40% to 100% (of that at the tip of the catheter) (n = 14), while the reduction in shunt flow following embolization ranged from 15% to 96% (n = 19). Tissue perfusion distal to the shunt and in the contralateral limb was about 5 ml 100 ml(-1) min(-1) Contrast medium had no consistent effect on tissue perfusion in either limb, or on shunt flow. There was no difference in peripheral perfusion between the abnormal and control sides, nor any significant difference in perfusion in the distal tissue on the abnormal side before and after embolization. There was, however, a consistent increase in the fraction of the injected Xe-133 delivered to the distal tissue after embolization (median increase 93%, p < 0.001). The technique is relatively simple and merits further development as a means of continuous quantification of systemic AV shunt flow in the angiography theatre at the time of embolization.
引用
收藏
页码:844 / 849
页数:6
相关论文
共 6 条
[1]  
ALLISON DJ, 1985, DIAGNOSTIC TECHNIQUE, P403
[3]   COMPLICATIONS OF EMBOLIZATION - ANALYSIS OF 410 PROCEDURES [J].
HEMINGWAY, AP ;
ALLISON, DJ .
RADIOLOGY, 1988, 166 (03) :669-672
[4]   RADIONUCLIDE LIMB BLOOD-FLOW IN PERIPHERAL VASCULAR-DISEASE - A REVIEW OF 1100 MEASUREMENTS [J].
PARKIN, A ;
ROBINSON, PJ ;
MARTINEZ, D ;
WILKINSON, D ;
KESTER, RC .
NUCLEAR MEDICINE COMMUNICATIONS, 1991, 12 (10) :835-851
[5]  
PARTSCH H, 1986, PHLEBOLOGY 85, P791
[6]  
SHEPHERD JT, 1983, HDB PHYSL CARDIOVASC, V3, P319