ANION EXCLUSION EFFECTS ON ESTIMATES OF SOIL CHLORIDE AND DEEP-PERCOLATION
被引:11
|
作者:
SLAVICH, PG
论文数: 0引用数: 0
h-index: 0
机构:N.S.W. Agriculture and Fisheries, Deniliquin, NSW, 2710
SLAVICH, PG
PETTERSON, GH
论文数: 0引用数: 0
h-index: 0
机构:N.S.W. Agriculture and Fisheries, Deniliquin, NSW, 2710
PETTERSON, GH
机构:
[1] N.S.W. Agriculture and Fisheries, Deniliquin, NSW, 2710
来源:
AUSTRALIAN JOURNAL OF SOIL RESEARCH
|
1993年
/
31卷
/
04期
关键词:
CHLORIDE;
DEEP PERCOLATION;
RECHARGE;
ANION EXCLUSION;
SOIL ANALYSIS;
D O I:
10.1071/SR9930455
中图分类号:
S15 [土壤学];
学科分类号:
0903 ;
090301 ;
摘要:
Anion exclusion affects estimates of deep percolation determined using chloride mass balance models. This paper evaluates potential errors arising from ignoring anion exclusion in both soil analysis methods and model assumptions. Soil chloride analysis from saturated paste and 1:5 soil/water extracts are compared with that of field soil water extracted using a filter paper technique. The influence of anion exclusion on estimates of soil water chloride concentration (Cl(SW) mmol/L) and chloride content per unit mass of sal (Cl(T) mmol/kg soil), both which are required by chloride mass balance models, is examined for these methods. The relative importance of total electrolyte concentration and sodium absorption ratio (SAR) on the anion exclusion volume of a clay was also determined using a simple laboratory leaching technique. The chloride concentration of soil water at field moisture contents was more closely related to estimates calculated from saturated paste extracts than from 1:5 soil/water extracts. Although the amount of excluded water estimated in the saturated paste was larger than that estimated at the field water content, the proportion of non-excluded water in each was similar. The Cl(T) was overestimated when analysis from saturation extracts was used. Electrolyte concentration and SAR were shown to have similar (but opposite) relative effects on the exclusion volume. However, because these variables were positively correlated, their effects were not apparent in the field samples. For the clay soil under study, deep percolation could be overestimated by up to 1.64 times if anion exclusion effects were ignored when using 1:5 extracts to estimate Cl(SW). The errors were considerably less if saturation extracts were used to estimate Cl(SW) and Cl(T).
机构:
Univ Paris 06, Sorbonne Univ, 4 Pl Jussieu, F-75252 Paris 05, France
ENS PSL Res Univ, 24 Rue Lhomond, F-75231 Paris 05, France
CNRS, UMR8538, Geol Lab, 24 Rue Lhomond, F-75231 Paris 05, FranceUniv Paris 06, Sorbonne Univ, 4 Pl Jussieu, F-75252 Paris 05, France
Dominguez, C. G.
Pryet, A.
论文数: 0引用数: 0
h-index: 0
机构:
Inst Polytech Bordeaux, EA 4592, 1 Allee Fernand Daguin, F-33607 Pessac, France
Univ Bordeaux Montaigne, 1 Allee Fernand Daguin, F-33607 Pessac, FranceUniv Paris 06, Sorbonne Univ, 4 Pl Jussieu, F-75252 Paris 05, France
Pryet, A.
Garcia Vera, M.
论文数: 0引用数: 0
h-index: 0
机构:
Natl Polytech Sch, Dept Phys, Quito, EcuadorUniv Paris 06, Sorbonne Univ, 4 Pl Jussieu, F-75252 Paris 05, France
Garcia Vera, M.
Gonzalez, A.
论文数: 0引用数: 0
h-index: 0
机构:
Natl Polytech Sch, Dept Civil & Environm Engn, Quito, EcuadorUniv Paris 06, Sorbonne Univ, 4 Pl Jussieu, F-75252 Paris 05, France
Gonzalez, A.
Chaumont, C.
论文数: 0引用数: 0
h-index: 0
机构:
IRSTEA UR HBAN, 1 Rue Pierre Gilles de Gennes, F-92761 Antony, FranceUniv Paris 06, Sorbonne Univ, 4 Pl Jussieu, F-75252 Paris 05, France
Chaumont, C.
Tournebize, J.
论文数: 0引用数: 0
h-index: 0
机构:
IRSTEA UR HBAN, 1 Rue Pierre Gilles de Gennes, F-92761 Antony, FranceUniv Paris 06, Sorbonne Univ, 4 Pl Jussieu, F-75252 Paris 05, France
Tournebize, J.
Villacis, M.
论文数: 0引用数: 0
h-index: 0
机构:
Natl Polytech Sch, Dept Civil & Environm Engn, Quito, EcuadorUniv Paris 06, Sorbonne Univ, 4 Pl Jussieu, F-75252 Paris 05, France
Villacis, M.
d'Ozouville, N.
论文数: 0引用数: 0
h-index: 0
机构:
Charles Darwin Fdn, Puerto Ayora, Galapagos Islan, EcuadorUniv Paris 06, Sorbonne Univ, 4 Pl Jussieu, F-75252 Paris 05, France