PESTICIDE;
GAS CHROMATOGRAPHY MASS SPECTROMETRY;
SELECTED ION MONITORING;
WATER SAMPLE;
GOLF COURSE;
D O I:
10.2116/analsci.7.247
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
The authors have developed an analytical method for determining trace amounts of 39 kinds of pesticides in water with high precision and accuracy by gas chromatography/mas spectrometry with a selected ion monitor (GC/MS-SIM). One liter of water was extracted with dichloromethane; the extract was concentrated to 1 ml with a Kuderna-Danish concentrator. After the internal standards, perdeuterated n-alkanes (C-16, C20 and C24), were added to the concentrate, quantitative analyses by GC/MS-SIM were performed to measure the recovery efficiencies of the 39 compounds spiked into water samples at concentrations of below mu-g/l. The recovery efficiencies of the tested compounds, except monocrotophos and bentazone, yielded more than 95% and their relative standard deviations were less than 6%. The developed method was applied to the determination of pesticides in river and tap water. Sixteen pesticides ranging from ng/l to mu-g/l were detected. This method is useful to elucidate the fates and the concentration levels of pesticides in the aquatic environment.