KINETIC-MODEL OF PH-BASED POTENTIOMETRIC ENZYMATIC SENSORS .1. THEORETICAL CONSIDERATIONS

被引:33
作者
GLAB, S
KONCKI, R
HULANICKI, A
机构
关键词
POTENTIOMETRIC ENZYMATIC PH SENSOR; KINETIC MODEL; STEADY-STATE RESPONSE;
D O I
10.1039/an9911600453
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A theoretical, kinetic model for a pH-based potentiometric enzymic sensor has been developed. It has been shown that the response of these sensors is governed by the pH, the buffering capacity of solutions analysed, and also the stirring rate. This model takes into account the variability of the kinetics of the enzymic reaction. The final equation is presented in an algebraic form and can be used in both fitting and optimization procedures.
引用
收藏
页码:453 / 458
页数:6
相关论文
共 21 条
[1]  
BELL PR, 1969, ACIDS BASES THEIR QU
[2]   KINETIC BEHAVIOR OF ENZYMES IMMOBILIZED IN ARTIFICIAL MEMBRANES [J].
BLAEDEL, WJ ;
BOGUSLASKI, RC ;
KISSEL, TR .
ANALYTICAL CHEMISTRY, 1972, 44 (12) :2030-+
[3]  
BOYER PD, 1970, ENZYMES, V1
[4]   THEORETICAL EVALUATION OF THE STEADY-STATE RESPONSE OF POTENTIOMETRIC ENZYME ELECTRODES [J].
BRADY, JE ;
CARR, PW .
ANALYTICAL CHEMISTRY, 1980, 52 (06) :977-980
[5]   PH-BASED ENZYME POTENTIOMETRIC SENSORS .3. PENICILLIN-SENSITIVE FIELD-EFFECT TRANSISTOR [J].
CARAS, SD ;
JANATA, J .
ANALYTICAL CHEMISTRY, 1985, 57 (09) :1924-1925
[6]   PH-BASED ENZYME POTENTIOMETRIC SENSORS .2. GLUCOSE-SENSITIVE FIELD-EFFECT TRANSISTOR [J].
CARAS, SD ;
PETELENZ, D ;
JANATA, J .
ANALYTICAL CHEMISTRY, 1985, 57 (09) :1920-1923
[7]   PH-BASED ENZYME POTENTIOMETRIC SENSORS .1. THEORY [J].
CARAS, SD ;
JANATA, J ;
SAUPE, D ;
SCHMITT, K .
ANALYTICAL CHEMISTRY, 1985, 57 (09) :1917-1920
[8]  
Carr P. W., 1980, IMMOBILIZED ENZYMES, P1980
[9]   RESPONSE OF AN ENZYME-MODIFIED PH-SENSITIVE ION-SELECTIVE DEVICE - CONSIDERATION OF THE INFLUENCE OF THE BUFFERING CAPACITY OF THE ANALYTE SOLUTION [J].
EDDOWES, MJ .
SENSORS AND ACTUATORS, 1985, 7 (02) :97-115
[10]   RESPONSE OF AN ENZYME-MODIFIED PH-SENSITIVE ION-SELECTIVE DEVICE - EXPERIMENTAL-STUDY OF A GLUCOSE OXIDASE MODIFIED ION-SENSITIVE FIELD-EFFECT TRANSISTOR IN BUFFERED AND UNBUFFERED AQUEOUS-SOLUTION [J].
EDDOWES, MJ ;
PEDLEY, DG ;
WEBB, BC .
SENSORS AND ACTUATORS, 1985, 7 (04) :233-244