Effective radiation dose reduction in computed tomography-guided spinal injections: a prospective, comparative study with technical considerations

被引:15
|
作者
Artner, Juraj [1 ]
Lattig, Friederike [1 ]
Reichel, Heiko [1 ]
Cakir, Balkan [1 ]
机构
[1] RKU, Univ Um, Dept Orthopaed Surg, Ulm, Germany
关键词
CT-guided spinal injections; periradicular; injection; computed tomography; lumbar spine; low dose protocol;
D O I
10.4081/or.2012.e24
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Despite the good general patient acceptance, high patient comfort, safety and precision in the needle placement, exposure to radiation in computed tomography (CT)guided spinal interventions remains a serious concern, and is often used to argue against its use. The aim of this study was to determine the technical possibilities of reducing the radiation dose in CT-guided epidural and periradicular injections in lumbar spine. We evaluated the possibilities of reducing radiation dose to the patient and operator during CT-guided injections on the lumbar spine using the following steps: significant reduction of the tube current and energy used for the topogram-acquisition, narrowing the area of interest in spiral CTmode and reduction of tube current and radiation energy in the final intervention mode. Fifty-three CT-guided spinal injections were performed in the lumbar spine (34 epidural lumbar, 19 lumbar periradicular) using a low-dose protocol in non-obese patients and compared with 1870 CT-guided injections from the year 2010, when a standard dose protocol was used. Technical considerations on radiation dose reduction were provided. An average dose reduction of 85% was achieved using the low-dose protocol in CTguided epidural and periradicular injections in lumbar spine without showing any effect on safety or precision.
引用
收藏
页码:109 / 112
页数:4
相关论文
共 21 条
  • [11] Radiation Dose Optimization Based on Saudi National Diagnostic Reference Levels and Effective Dose Calculation for Computed Tomography Imaging: A Unicentral Cohort Study
    Al-Othman, Abdullah Yousef
    Al-Sharydah, Abdulaziz Mohammad
    Abuelhia, Elfatih Ibrahim
    Mohtasib, Rafat
    Bin Dahmash, Abdulmajeed
    Hegazi, Tarek Mohammed
    Tajaldeen, Abdulrahman Amin
    Alshehri, Sultan Salman
    Al-Malki, Fahad Mabruk
    Alghamdi, Salem
    APPLIED SCIENCES-BASEL, 2022, 12 (22):
  • [12] Comparison of Effective Dose of Radiation During Pedicle Screw Placement Using Intraoperative Computed Tomography Navigation Versus Fluoroscopy in Children With Spinal Deformities
    Richerand, Alejandro Dabaghi
    Christodoulou, Emmanuel
    Li, Ying
    Caird, Michelle S.
    Jong, Nahbee
    Farley, Frances A.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2016, 36 (05) : 530 - 533
  • [13] Effects of a radiation dose reduction strategy for computed tomography in severely injured trauma patients in the emergency department: an observational study
    Soo Hyun Kim
    Seung Eun Jung
    Sang Hoon Oh
    Kyu Nam Park
    Chun Song Youn
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 19
  • [14] Reduction of radiation dose for coronary computed tomography angiography using prospective electrocardiography-triggered high-pitch acquisition in clinical routine
    Chaosuwannakit, Narumol
    Makarawate, Pattarapong
    POLISH JOURNAL OF RADIOLOGY, 2018, 83 : E260 - E267
  • [15] Evaluating the precision of ultrasound versus computed tomography-guided measurement of cricoid cartilage diameter for double-lumen tube selection in thoracic surgery: A randomised comparative study
    Mathew, Roshni M.
    Gautam, Shefali
    Raman, Rajesh
    Rai, Anurag
    Srivastava, Vinod K.
    Singh, Manish K.
    INDIAN JOURNAL OF ANAESTHESIA, 2024, 68 (10) : 896 - 901
  • [16] Influence of the adaptive iterative dose reduction 3D algorithm on the detectability of low-contrast lesions and radiation dose repeatability in abdominal computed tomography: a phantom study
    Yoon, Jeong Hee
    Lee, Jeong Min
    Hur, Bo Yun
    Baek, Jeehyun
    Shim, Hackjoon
    Han, Joon Koo
    Choi, Byung Ihn
    ABDOMINAL IMAGING, 2015, 40 (06): : 1843 - 1852
  • [17] Influence of the adaptive iterative dose reduction 3D algorithm on the detectability of low-contrast lesions and radiation dose repeatability in abdominal computed tomography: a phantom study
    Jeong Hee Yoon
    Jeong Min Lee
    Bo Yun Hur
    Jeehyun Baek
    Hackjoon Shim
    Joon Koo Han
    Byung Ihn Choi
    Abdominal Imaging, 2015, 40 : 1843 - 1852
  • [18] Advances in spatial resolution and radiation dose reduction using super- resolution deep learning-based reconstruction for abdominal computed tomography: A phantom study
    Funama, Yoshinori
    Nagayama, Yasunori
    Sakabe, Daisuke
    Ito, Yuya
    Chiba, Yutaka
    Nakaura, Takeshi
    Oda, Seitaro
    Kidoh, Masafumi
    Hirai, Toshinori
    ACADEMIC RADIOLOGY, 2025, 32 (03) : 1517 - 1524
  • [19] Variability of repeated coronary artery calcium scoring and radiation dose on 64-and 16-slice computed tomography by prospective electrocardiographically-triggered axial and retrospective electrocardiographically-gated spiral computed tomography: A phantom study
    Horiguchi, Jun
    Kiguchi, Masao
    Fujioka, Chikako
    Arie, Ryuichi
    Shen, Yun
    Sunasaka, Kenichi
    Kitagawa, Toshiro
    Yamamoto, Hideya
    Ito, Katsuhide
    ACADEMIC RADIOLOGY, 2008, 15 (08) : 958 - 965
  • [20] A CONSORT-compliant prospective randomized controlled trial: radiation dose reducing in computed tomography using an additional lateral scout view combined with automatic tube current modulation Phantom and patient study
    Peng, Wanlin
    Li, Zhenlin
    Xia, Chunchao
    Guo, Yingkun
    Zhang, Jinge
    Zhang, Kai
    Li, Lei
    Zhao, Fei
    MEDICINE, 2017, 96 (30)