Effective radiation dose reduction in computed tomography-guided spinal injections: a prospective, comparative study with technical considerations

被引:15
|
作者
Artner, Juraj [1 ]
Lattig, Friederike [1 ]
Reichel, Heiko [1 ]
Cakir, Balkan [1 ]
机构
[1] RKU, Univ Um, Dept Orthopaed Surg, Ulm, Germany
关键词
CT-guided spinal injections; periradicular; injection; computed tomography; lumbar spine; low dose protocol;
D O I
10.4081/or.2012.e24
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Despite the good general patient acceptance, high patient comfort, safety and precision in the needle placement, exposure to radiation in computed tomography (CT)guided spinal interventions remains a serious concern, and is often used to argue against its use. The aim of this study was to determine the technical possibilities of reducing the radiation dose in CT-guided epidural and periradicular injections in lumbar spine. We evaluated the possibilities of reducing radiation dose to the patient and operator during CT-guided injections on the lumbar spine using the following steps: significant reduction of the tube current and energy used for the topogram-acquisition, narrowing the area of interest in spiral CTmode and reduction of tube current and radiation energy in the final intervention mode. Fifty-three CT-guided spinal injections were performed in the lumbar spine (34 epidural lumbar, 19 lumbar periradicular) using a low-dose protocol in non-obese patients and compared with 1870 CT-guided injections from the year 2010, when a standard dose protocol was used. Technical considerations on radiation dose reduction were provided. An average dose reduction of 85% was achieved using the low-dose protocol in CTguided epidural and periradicular injections in lumbar spine without showing any effect on safety or precision.
引用
收藏
页码:109 / 112
页数:4
相关论文
共 21 条
  • [1] Reduced Kilovoltage in Computed Tomography-Guided Intervention in a Community Hospital: Effect on the Radiation Dose
    Rezazadeh, Saman
    Co, Steven J.
    Bicknell, Simon
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2014, 65 (04): : 345 - 351
  • [2] Safety profile and technical success rate of computed tomography-guided atlanto-axial lateral articulation injections
    Liou, Harris
    Diehn, Felix E.
    Lehman, Vance T.
    Murthy, Naveen S.
    Carr, Carrie M.
    Madhavan, Ajay A.
    Benson, John C.
    Oien, Michael P.
    Kim, Dong Kun
    PAIN MEDICINE, 2023, 24 (07) : 782 - 786
  • [3] Computed tomography-guided cutting needle biopsy for lung nodules A comparative study between low-dose and standard dose protocols
    Zhang, Hui-Mei
    Huo, Xiao-Bing
    Wang, Hua-Long
    Zhang, Xiao
    Fu, Yu-Fei
    MEDICINE, 2021, 100 (03) : E24001
  • [4] Reducing cranial computed tomography effective radiation dose by 30% using adaptive iterative dose reduction
    Yu, Wai-Yung
    Ho, Thye Sin
    Ko, Henry
    Chan, Wai-Yee
    Ong, Serene
    Hui, Francis Kim Hoong
    PROCEEDINGS OF SINGAPORE HEALTHCARE, 2016, 25 (04) : 230 - 234
  • [5] Computed tomography versus fluoroscopic guided-sacroiliac joint injection: a prospective comparative study
    Bessar, Ahmed A. A.
    Arnaout, Mohamed M.
    Basha, Mohammad Abd Alkhalik
    Shaker, Shady E.
    Elsayed, Ashraf E.
    Bessar, Manar Awad
    INSIGHTS INTO IMAGING, 2021, 12 (01)
  • [6] Computed tomography versus fluoroscopic guided-sacroiliac joint injection: a prospective comparative study
    Ahmed A. A. Bessar
    Mohamed M. Arnaout
    Mohammad Abd Alkhalik Basha
    Shady E. Shaker
    Ashraf E. Elsayed
    Manar Awad Bessar
    Insights into Imaging, 12
  • [7] A comparative study for image quality and radiation dose of a cone beam computed tomography scanner and a multislice computed tomography scanner for paranasal sinus imaging
    De Cock, Jens
    Zanca, Federica
    Canning, John
    Pauwels, Ruben
    Hermans, Robert
    EUROPEAN RADIOLOGY, 2015, 25 (07) : 1891 - 1900
  • [8] A comparative study for image quality and radiation dose of a cone beam computed tomography scanner and a multislice computed tomography scanner for paranasal sinus imaging
    Jens De Cock
    Federica Zanca
    John Canning
    Ruben Pauwels
    Robert Hermans
    European Radiology, 2015, 25 : 1891 - 1900
  • [9] Evaluation of surface dose and image quality using the half-scan mode in chest computed tomography-guided interventional radiology: a phantom study
    Hasegawa H.
    Sato J.
    Kobayashi I.
    Radiological Physics and Technology, 2018, 11 (2) : 138 - 148
  • [10] Effects of a radiation dose reduction strategy for computed tomography in severely injured trauma patients in the emergency department: An observational study
    Kim, Soo Hyun
    Jung, Seung Eun
    Oh, Sang Hoon
    Park, Kyu Nam
    Youn, Chun Song
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2011, 19