High stability piezoelectric force sensor.

被引:0
|
作者
Audigier, D
Richard, C
Descamps, C
Eyraud, L
机构
来源
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Many dynamic stress sensors use piezoelectric ceramics. They are active sensors, generally broadband for low frequency applications. It is usual that a high static stress is superimposed to the dynamic stress to be measured (hydrophones, force ring sensors, etc.). In this case, the active part has to commit with two important conditions: 1 degrees) the use of a material presenting the most linear behavior in the working force range. 2 degrees) the use of a geometry bringing a stress repartition favoring a linear behavior of the material. The original proposed solution is a sensor made with two parts mechanically and electrically serie connected. Each part with a different geometry has a specific variation with the applied force. It is shown that for an adequate configuration, both variations compensate allowing a great stability of the assembly.
引用
收藏
页码:457 / 460
页数:4
相关论文
共 50 条
  • [31] OPTICAL THERMAL SENSOR.
    Kikuta, Toshio
    Tanaka, Takashi
    Kashiwayanagi, Yuzo
    Furukawa Denko Jiho/ Furukawa Electric Review, 1981, (72): : 69 - 73
  • [32] ELECTROSTATIC VOLTAGE SENSOR.
    Inaba, Ritsuo
    Kasahara, Yukio
    National technical report, 1980, 26 (03): : 473 - 479
  • [33] DESIGN CONSIDERATIONS ON HIGH SENSITIVITY MOS AREA IMAGE SENSOR.
    Ohba, Shinya
    Nakai, Masaaki
    Ando, Haruhisa
    Kubo, Masaharu
    Shimada, Shigeru
    Electronics & communications in Japan, 1980, 63 (03): : 96 - 105
  • [34] Calibration method of piezoelectric dynamic force sensor
    Lu X.
    Zhai Q.
    Tu C.
    Fan H.
    Hu H.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2021, 40 (05): : 261 - 265
  • [35] Piezoelectric bimorph charge mode force sensor
    Kursu, Olli
    Kruusing, Arvi
    Pudas, Marko
    Rahkonen, Timo
    SENSORS AND ACTUATORS A-PHYSICAL, 2009, 153 (01) : 42 - 49
  • [36] Development of a piezoelectric force sensor for a chip refiner
    Siadat, A
    Bankes, A
    Wild, PM
    Senger, J
    Ouellet, D
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2003, 217 (E2) : 133 - 140
  • [37] Stability, response time, and inter-sensor variability of the Medtronic MiniMed subcutaneous glucose sensor.
    Rebrin, K
    Steil, GM
    Janowski, R
    Dangui, N
    Kanderian, S
    Hwu, CM
    Hariri, F
    Jinagouda, S
    Darwin, C
    Saad, M
    DIABETOLOGIA, 2003, 46 : A309 - A310
  • [38] INTERCEPTOR RADAR EVOLVES AS A SENSOR.
    Spooner, P.W.
    Microwaves and RF, 1985, 24 (03): : 127 - 130
  • [39] COLLISION-PREVENTION SENSOR.
    Anon
    IBM technical disclosure bulletin, 1985, 28 (07): : 2925 - 2926
  • [40] OPTICAL SHAFT POSITION SENSOR.
    Brown, V.O.
    Newman, W.S.
    Technical Digest - AT&T Technologies, 1986, (78):