SENSITIVITY OF RANDOM-DOT STEREOACUITY AND SNELLEN ACUITY TO OPTICAL BLUR

被引:30
|
作者
SCHMIDT, PP
机构
[1] Exceptional Child and Infant Vision Testing Laboratory, College of Optometry, The Ohio State University, Columbus, OH
关键词
OPTICAL BLUR; RANDOM DOT STEREOACUITY (RDS); REFRACTIVE AMBLYOPIA; SNELLEN VISUAL ACUITY; VISION SCREENING;
D O I
10.1097/00006324-199407000-00007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of this study is to investigate the usefulness of a random dot stereogram for the detection of refractive blur by determining the relative sensitivity of random dot stereoacuity (RDS) and Snellen visual acuity to the effects of optically induced blur. Measurements of Snellen and stereoacuity were completed on four young adult subjects under cycloplegia and through artificial pupils. Optical blur was varied binocularly and monocularly in 0.50 D steps up to +/- 6.00 D while the subjects viewed targets composed of stimuli arranged in 0.1 log unit size increments. The results show the relation between RDS and Snellen acuity to be SA = 1.341 (VA) + 0.281 for equal amounts of binocularly induced optical blur. Moreover, the RDS appeared more highly sensitive when the blur in the 2 eyes was unequal [SA = 3.774 (VA) - 1.180], a condition approximating refractive anisometropic amblyopia. These results provide a rationale for the use of random element stereograms for the detection of refractive amblyopia and ametropia in the vision screening of children.
引用
收藏
页码:466 / 471
页数:6
相关论文
共 50 条
  • [1] Stereoacuity Improvement using Random-Dot Video Games
    Martin-Gonzalez, Santiago
    Portela-Camino, Juan
    Ruiz-Alcocer, Javier
    Illarramendi-Mendicute, Igor
    Garrido-Mercado, Rafaela
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (155):
  • [2] The effect of dot size in random-dot stereograms on the results of stereoacuity measurements
    Zhao, Lingzhi
    Wu, Huang
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [3] The effect of dot size in random-dot stereograms on the results of stereoacuity measurements
    Lingzhi Zhao
    Huang Wu
    BMC Ophthalmology, 20
  • [4] STEREOSCOPIC ACUITY WITH MOVING RANDOM-DOT PATTERNS
    LAPPIN, JS
    ANDERSON, BL
    CRAFT, WD
    PAYNE, TL
    BULLETIN OF THE PSYCHONOMIC SOCIETY, 1984, 22 (04) : 288 - 288
  • [5] RANDOM-DOT STEREOACUITY FOLLOWING SURGICAL-CORRECTION OF INFANTILE ESOTROPIA
    BIRCH, EE
    STAGER, DR
    EVERETT, ME
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 1995, 32 (04) : 231 - 235
  • [6] RANDOM-DOT STEREOACUITY FOLLOWING SURGICAL-CORRECTION OF INFANTILE ESOTROPIA
    BIRCH, EE
    STAGER, DR
    EVERETT, ME
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1830 - 1830
  • [7] EFFECTS OF DIOPTRIC BLUR ON SNELLEN AND GRATING ACUITY
    THORN, F
    SCHWARTZ, F
    OPTOMETRY AND VISION SCIENCE, 1990, 67 (01) : 3 - 7
  • [8] The effects of diffusion blur on Snellen and grating acuity in amblyopia
    Han, SH
    Kim, SK
    Lee, JB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1287 - 1287
  • [9] RANDOM-DOT PICTURE SAMPLING BY OPTICAL PROJECTION
    HEARD, PF
    MAKEPEACE, APW
    BEHAVIOR RESEARCH METHODS & INSTRUMENTATION, 1980, 12 (01): : 45 - 47
  • [10] EFFECT OF INDUCED BLUR ON VISUAL-ACUITY AND STEREOACUITY
    LARSON, WL
    BOLDUC, M
    OPTOMETRY AND VISION SCIENCE, 1991, 68 (04) : 294 - 298