HISTOLOGIC INVESTIGATION OF THE BIOLOGIC BEHAVIOR OF DIFFERENT HYDROXYAPATITE PLASMA-SPRAYED COATINGS IN RABBITS

被引:71
作者
JANSEN, JA [1 ]
VANDERWAERDEN, JPCM [1 ]
WOLKE, JGC [1 ]
机构
[1] LEIDEN UNIV,SCH MED,DEPT BIOMAT,2333 AA LEIDEN,NETHERLANDS
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1993年 / 27卷 / 05期
关键词
D O I
10.1002/jbm.820270507
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to investigate bone response to and biostability of three different hydroxyapatite (HA)-coatings. Therefore, coated and uncoated titanium implants were inserted into the tibia of rabbits. Implantation times were at 3 and 12 weeks. The histological evaluation included measurement of the amount of bone apposition to the various implant surfaces. The results demonstrated at 3 and 12 weeks no marked differences in bony reaction at the cortical level to the different implant materials. However, compared with the 3-week specimens, at 12 weeks extensive maturation of the woven bone callus had occurred. In addition, all t2-week implants induced bone formation in the medullary cavity. It was also noted that all HA-coatings showed loss of coating thickness. Quantitative determination of bone contact demonstrated that all 12-week implants showed the same high amount of bone apposition.
引用
收藏
页码:603 / 610
页数:8
相关论文
共 17 条
[1]  
Chae J C, 1988, Ann N Y Acad Sci, V523, P81, DOI 10.1111/j.1749-6632.1988.tb38502.x
[2]   PLASMA SPRAYED COATINGS OF HYDROXYLAPATITE [J].
DEGROOT, K ;
GEESINK, R ;
KLEIN, CPAT ;
SEREKIAN, P .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (12) :1375-1381
[3]   A HISTOLOGICAL AND HISTOMORPHOMETRICAL INVESTIGATION OF FLUORAPATITE, MAGNESIUMWHITLOCKITE, AND HYDROXYLAPATITE PLASMA-SPRAYED COATINGS IN GOATS [J].
DHERT, WJA ;
KLEIN, CPAT ;
JANSEN, JA ;
VANDERVELDE, EA ;
VRIESDE, RC ;
ROZING, PM ;
DEGROOT, K .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (01) :127-138
[4]  
GERNER BT, 1988, SCAND J DENT RES, V96, P143
[5]  
Groot K, 1981, BIOCOMPATIBILITY CLI, P199
[6]   HISTOLOGIC EVALUATION OF THE OSSEOUS ADAPTATION TO TITANIUM AND HYDROXYAPATITE-COATED TITANIUM IMPLANTS [J].
JANSEN, JA ;
VANDEWAERDEN, JPCM ;
WOLKE, JGC ;
DEGROOT, K .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (08) :973-989
[7]  
KLEIN CPA, 1991, NOV P IMECHE SEM FUT
[8]   STUDIES OF THE SOLUBILITY OF DIFFERENT CALCIUM-PHOSPHATE CERAMIC PARTICLES INVITRO [J].
KLEIN, CPAT ;
DEBLIECKHOGERVORST, JMA ;
WOLKE, JGC ;
DEGROOT, K .
BIOMATERIALS, 1990, 11 (07) :509-512
[9]  
KLEIN CPAT, 1986, BIOMATERIALS, V7, P144
[10]   WORKSHOP ON CHARACTERIZATION OF CALCIUM-PHOSPHATE MATERIALS [J].
KOENEMAN, J ;
LEMONS, J ;
DUCHEYNE, P ;
LACEFIELD, W ;
MAGEE, F ;
CALAHAN, T ;
KAY, J .
JOURNAL OF APPLIED BIOMATERIALS, 1990, 1 (01) :79-90