DETERMINATION OF ATRAZINE IN WATER USING TANDEM HIGH-PERFORMANCE IMMUNOAFFINITY CHROMATOGRAPHY AND REVERSED-PHASE LIQUID-CHROMATOGRAPHY

被引:81
作者
THOMAS, DH [1 ]
BECKWESTERMEYER, M [1 ]
HAGE, DS [1 ]
机构
[1] UNIV NEBRASKA,DEPT CHEM,LINCOLN,NE 68588
关键词
D O I
10.1021/ac00093a044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fully automated HPLC method was developed for the analysis of atrazine in water. This method used a high-performance immunoaffinity column for the extraction of atrazine and other triazines from samples, followed by separation of the retained compounds with an on-line reversed-phase column. This technique used only 250 mu L Of Sample and required minimal sample pretreatment. Atrazine determinations by this method showed no significant interferences from the sample matrix, related triazines, or several common pesticides tested. Atrazine plus ail of its major degradation products could be determined in 20 min, with a throughput of 10 min per injection. A more rapid scheme for measuring atrazine alone was also developed, with a total analysis time of 12 min and a throughput of 6 min per injection. The calibration curve for atrazine was linear over 2 orders of magnitude and had a lower limit of detection of 0.1 mu g/L. The within-day precision was +/-5.4% for samples containing 1.1 mu g/L atrazine. The results of this method showed good correlation with those obtained by GC/MS or GC/NPD. By using different immunoaffinity columns and elution conditions, this method could be adapted for use in the determination of other compounds of environmental interest.
引用
收藏
页码:3823 / 3829
页数:7
相关论文
共 36 条
[11]  
HAGE DS, 1987, J CHROMATOGR, V386, P37
[12]   HIGH-PERFORMANCE IMMUNOAFFINITY CHROMATOGRAPHY AND CHEMILUMINESCENT DETECTION IN THE AUTOMATION OF A PARATHYROID-HORMONE SANDWICH IMMUNOASSAY [J].
HAGE, DS ;
KAO, PC .
ANALYTICAL CHEMISTRY, 1991, 63 (06) :586-595
[13]   NON-LINEAR ELUTION EFFECTS IN SPLIT-PEAK CHROMATOGRAPHY .1. COMPUTER-SIMULATIONS FOR THE CASES OF IRREVERSIBLE DIFFUSION-LIMITED AND ADSORPTION-LIMITED KINETICS [J].
HAGE, DS ;
WALTERS, RR .
JOURNAL OF CHROMATOGRAPHY, 1988, 436 (02) :111-135
[14]  
HARLOW E, 1988, ANTIBODIES LABORATOR, pCH8
[15]   COMPARISON OF REVERSED-PHASE EXTRACTION SORBENTS FOR THE ONLINE TRACE ENRICHMENT OF POLAR ORGANIC-COMPOUNDS IN ENVIRONMENTAL AQUEOUS SAMPLES [J].
HENNION, MC ;
COQUART, V .
JOURNAL OF CHROMATOGRAPHY, 1993, 642 (1-2) :211-224
[16]   IMMUNOLOGICAL-CHROMATOGRAPHIC ANALYSIS [J].
JANIS, LJ ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1988, 444 :1-11
[17]   SIMPLIFIED QUANTITATIVE-DETERMINATION OF PLASMA PHENYTOIN - ONLINE PRECOLUMN HIGH-PERFORMANCE LIQUID IMMUNOAFFINITY CHROMATOGRAPHY WITH SAMPLE PRE-PURIFICATION [J].
JOHANSSON, B .
JOURNAL OF CHROMATOGRAPHY, 1986, 381 (01) :107-113
[18]   ORGANICS IN WATER - SOLID-PHASE EXTRACTION ON A SMALL-SCALE [J].
JUNK, GA ;
RICHARD, JJ .
ANALYTICAL CHEMISTRY, 1988, 60 (05) :451-454
[19]   INTERFERENCES IN SOLID-PHASE EXTRACTION USING C-18 BONDED POROUS SILICA CARTRIDGES [J].
JUNK, GA ;
AVERY, MJ ;
RICHARD, JJ .
ANALYTICAL CHEMISTRY, 1988, 60 (13) :1347-1350
[20]  
KARU AE, 1990, IMMUNOASSAYS TRACE C, pCH6