GRIP STRENGTH TESTING USING THE BTE WORK SIMULATOR AND THE JAMAR DYNAMOMETER - A COMPARATIVE-STUDY

被引:32
作者
BEATON, DE [1 ]
ODRISCOLL, SW [1 ]
RICHARDS, RR [1 ]
机构
[1] ST MICHAELS HOSP,UPPER EXTREM RECONSTRUCT SERV,TORONTO,ON,CANADA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 1995年 / 20A卷 / 02期
关键词
D O I
10.1016/S0363-5023(05)80029-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study compared the results obtained from testing grip strength using the hydraulic Jamar dynamometer and the BTE Work Simulator. The grip strength of 14 adults was assessed with the Jamar at 90 degrees elbow flexion, Jamar at 45 degrees elbow flexion, and the BTE using the manufacturers recommended position. Greater strength measurements were generated with the elbow at 90 degrees rather than 45 degrees on the Jamar. The Jamar measurements at 90 degrees of elbow flexion were not significantly different from the BTE work simulator values. Intraclass correlation coefficients between the Jamar at 90 degrees and the BTE work simulator values were excellent. This study demonstrated that the results obtained from the BTE work simulator and the Jamar dynamometer are comparable. These findings validate the use of the BTE work simulator for grip strength testing.
引用
收藏
页码:293 / 298
页数:6
相关论文
共 31 条
  • [1] Fess, The need for reliability and validity in hand assessment instruments, J Hand Surg, 11 A, pp. 621-623, (1986)
  • [2] Fess, Documentation: Essential elements of an upper extremity assessment battery, Rehabilitation of the hand, pp. 53-81, (1990)
  • [3] Feinstein, Clinemetrics, pp. 141-211, (1987)
  • [4] Bear-Lehman, Abreu, Evaluating the Hand: Issues in reliability and validity, Phys Ther, 69, pp. 1025-1033, (1989)
  • [5] Jones, Assessment of hand function: a critical review of techniques, J Hand Surg, 14 A, pp. 221-228, (1989)
  • [6] Fess, The effects of Jamar handle position and test protocol on normal grip strength, The Journal of Hand Surgery, 7 A, (1982)
  • [7] Mathiowetz, Weber, Volland, Kashmand, Reliability and validity of hand strength evaluation, J Hand Surg, 9 A, pp. 222-226, (1984)
  • [8] Mathiowetz, Kashman, Volland, Weber, Dowe, Rogers, Grip and pinch strength: Normative data for adults, Arch Phys Med Rehabil, 66, pp. 69-74, (1985)
  • [9] Mathiowetz, Rennells, Donahoe, Effect of elbow position on grip and key pinch strength, J Hand Surg, 10 A, pp. 694-697, (1985)
  • [10] Richards, Gordon, Beaton, Measurement of wrist, metacarpophalangeal joint and thumb extension in a normal population, J Hand Surg, 18 A, pp. 253-261, (1993)