DROPLET ELECTROSPRAY MASS-SPECTROMETRY

被引:69
作者
HAGER, DB [1 ]
DOVICHI, NJ [1 ]
KLASSEN, J [1 ]
KEBARLE, P [1 ]
机构
[1] UNIV ALBERTA,DEPT CHEM,EDMONTON T6G 2G2,AB,CANADA
关键词
D O I
10.1021/ac00094a015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In droplet electrospray (DES), a stream of uncharged droplets with a controlled radius between 6 and 50 mu m and at frequencies in the 100 kHz range is produced by vibrating the capillary tip with a piezoelectric buzzer. The droplets are then charged by letting the droplet stream pass close to a 50 mu m diameter rod electrode that is at 3 kV and is producing an electric discharge in the ambient air. The charged droplets are destabilized by the charge and emit a fine spray of offspring droplets. These events can be observed with a stroboscopic technique. The observed droplet fission is very similar in appearance to that reported by Gomez and Tang. The gas phase ions produced by the droplet fission (droplet spray) are detected with a mass spectrometer. The mass spectra are close to identical to spectra observed with conventional electrospray. Additional development of DES could lead to a technique that is analytically competitive with conventional ESMS. The present DES results provide some important insights into the mechanism of conventional ES.
引用
收藏
页码:3944 / 3949
页数:6
相关论文
共 16 条
[1]  
Bailey A.G., 1988, ELECTROSTATIC SPRAYI
[2]   MECHANISM OF ELECTROSPRAY MASS-SPECTROMETRY - ELECTROSPRAY AS AN ELECTROLYSIS CELL [J].
BLADES, AT ;
IKONOMOU, MG ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1991, 63 (19) :2109-2114
[3]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[4]   TECHNIQUE FOR PRODUCING CAPILLARIES WITH REPRODUCIBLE ORIFICE DIAMETERS FOR UNIFORM DROPLET GENERATION [J].
GALLEY, PJ ;
HIEFTJE, GM .
APPLIED SPECTROSCOPY, 1992, 46 (10) :1460-1463
[5]   CHARGE AND FISSION OF DROPLETS IN ELECTROSTATIC SPRAYS [J].
GOMEZ, A ;
TANG, KQ .
PHYSICS OF FLUIDS, 1994, 6 (01) :404-414
[6]  
GUEVREMONT R, IN PRESS ORG MASS SP
[7]   BEHAVIOR OF MICROSCOPIC LIQUID DROPLETS NEAR A STRONG ELECTROSTATIC-FIELD - DROPLET ELECTROSPRAY [J].
HAGER, DB ;
DOVICHI, NJ .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1593-1594
[8]   INVESTIGATIONS OF THE ELECTROSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
IKONOMOU, MG ;
BLADES, AT ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1990, 62 (09) :957-967
[9]   On the evaporation of small ions from charged droplets [J].
IRIBARNE, JV ;
THOMSON, BA .
JOURNAL OF CHEMICAL PHYSICS, 1976, 64 (06) :2287-2294
[10]   FROM IONS IN SOLUTION TO IONS IN THE GAS-PHASE - THE MECHANISM OF ELECTROSPRAY MASS-SPECTROMETRY [J].
KEBARLE, P ;
TANG, L .
ANALYTICAL CHEMISTRY, 1993, 65 (22) :A972-A986