TILT AND DECENTRATION OF BAG-FIXATED INTRAOCULAR LENSES - A COMPARATIVE-STUDY BETWEEN CAPSULORHEXIS AND ENVELOPE TECHNIQUES

被引:31
作者
AKKIN, C [1 ]
OZLER, SA [1 ]
MENTES, J [1 ]
机构
[1] EGE UNIV,SCH MED,DEPT OPHTHALMOL,IZMIR 35100,TURKEY
关键词
ANTERIOR CAPSULOTOMY; CONTINUOUS CIRCULAR CAPSULORHEXIS; DECENTRATION; ENVELOPE; INTRAOCULAR LENS; TILT;
D O I
10.1007/BF01203850
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Malposition of an intraocular lens (IOL) may cause symptoms such as glare, halos, and other visual aberrations. The purpose of this study is to determine the effect of two different anterior capsulotomy techniques on IOL tilt and decentration. Bag-fixated IOL implantation after uncomplicated extracapsular cataract extraction was performed using both envelope (65 eyes) and continuous circular capsulorhexis (CCC) technique (42 eyes). Eyes were followed-up at least 6 months postoperatively. While the mean IOL decentration after envelope technique was found to be 0.65 mm, this was 0.15 mm after CCC technique. On the other hand, the mean actual tilting angle of IOL after envelope technique was 5.66 degrees, whereas this was 1.13 degrees after CCC technique. The aforementioned differences were statistically significant (p<0.01, and p<0.01). Furthermore, in 17 eyes (26.1%) where envelope technique and in 29 (69.0%) eyes where CCC technique was used demonstrated no IOL tilt and decentration. This study shows that the CCC technique may result in less optical problems due to IOL malposition compared to the envelope technique.
引用
收藏
页码:199 / 209
页数:11
相关论文
共 17 条
[1]  
ASSIA EI, 1991, OPHTHALMOLOGY, V98, P432
[2]   INVIVO MEASUREMENT OF POSTERIOR CHAMBER INTRAOCULAR-LENS DECENTRATION AND TILT [J].
AURAN, JD ;
KOESTER, CJ ;
DONN, A .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (01) :75-79
[3]   POSTERIOR CHAMBER INTRAOCULAR LENSES IN A SERIES OF 75 AUTOPSY EYES .3. CORRELATION OF POSITIONING HOLES AND OPTIC EDGES WITH THE PUPILLARY APERTURE AND VISUAL AXIS [J].
BREMS, RN ;
APPLE, DJ ;
PFEFFER, BR ;
PARK, SB ;
PIEST, KL ;
ISENBERG, RA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1986, 12 (04) :367-371
[4]   DECENTRATION OF INTRAOCULAR LENSES IMPLANTED AFTER INTERCAPSULAR CATARACT-EXTRACTION (ENVELOPE TECHNIQUE) [J].
CABALLERO, A ;
LOSADA, M ;
LOPEZ, JM ;
GALLEGO, L ;
SULLA, O ;
LOPEZ, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (03) :330-334
[5]  
CABALLERO A, 1993, EUR IMPLANT REF SURG, V5, P88
[6]   INTRAOCULAR-LENS CENTRATION WITH CONTINUOUS TEAR CAPSULOTOMY [J].
COLVARD, DM ;
DUNN, SA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (03) :312-314
[8]   DEVELOPMENT, ADVANTAGES, AND METHODS OF THE CONTINUOUS CIRCULAR CAPSULORHEXIS TECHNIQUE [J].
GIMBEL, HV ;
NEUHANN, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (01) :31-37
[9]  
GUYTON DL, 1990, OPHTHALMOLOGY, V97, P1259
[10]  
HANSEN SO, 1988, OPHTHALMOLOGY, V95, P344