VISUAL EVOKED-POTENTIAL MONITORING OF OPTIC-NERVE FUNCTION DURING SURGERY

被引:42
作者
HARDING, GFA
BLAND, JDP
SMITH, VH
机构
[1] BIRMINGHAM & MIDLAND EYE HOSP,BIRMINGHAM,ENGLAND
[2] QUEEN ELIZABETH HOSP,BIRMINGHAM B15 2TH,W MIDLANDS,ENGLAND
关键词
D O I
10.1136/jnnp.53.10.890
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
A study was made with intra-operative flash-visual evoked potentials (VEP) monitored using a fibre-optic/contact lens photo stimulator in 57 patients undergoing intra-orbital surgical procedures with potential risk to the optic nerve. The VEPs recorded under enflurane and nitrous oxide anaesthesia did not differ significantly in latency or amplitude from the pre-operative recordings. Transient abolition of the VEP was seen under many circumstances and did not correlate with the outcome of surgery, but absence of a previously normal VEP for more than four minutes during surgical manipulation within the orbit did show a correlation with post operative impairment of vision. The technique provides early warning to the surgeon of threats to the integrity of the optic nerve.
引用
收藏
页码:890 / 895
页数:6
相关论文
共 15 条
  • [1] CAVITRON ULTRASONIC SURGICAL ASPIRATOR AND VISUAL EVOKED-POTENTIAL MONITORING FOR CHIASMAL GLIOMAS IN CHILDREN - REPORT OF 2 CASES
    ALBRIGHT, AL
    SCLABASSI, RJ
    [J]. JOURNAL OF NEUROSURGERY, 1985, 63 (01) : 138 - 140
  • [2] Allen A, 1981, Clin Neurosurg, V28, P457
  • [3] FACTORS THAT LIMIT THE USE OF FLASH VISUAL EVOKED-POTENTIALS FOR SURGICAL MONITORING
    CEDZICH, C
    SCHRAMM, J
    MENGEDOHT, CF
    FAHLBUSCH, R
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1988, 71 (02): : 142 - 145
  • [4] ARE FLASH-EVOKED VISUAL POTENTIALS USEFUL FOR INTRAOPERATIVE MONITORING OF VISUAL PATHWAY FUNCTION
    CEDZICH, C
    SCHRAMM, J
    FAHLBUSCH, R
    [J]. NEUROSURGERY, 1987, 21 (05) : 709 - 715
  • [5] NEUROPHYSIOLOGIC EFFECTS OF GENERAL ANESTHETICS .1. ELECTROENCEPHALOGRAM AND SENSORY EVOKED-RESPONSES IN MAN
    CLARK, DL
    ROSNER, BS
    [J]. ANESTHESIOLOGY, 1973, 38 (06) : 564 - 582
  • [6] Costa e Silva I, 1985, Neurol Res, V7, P11
  • [7] MONITORING OPTIC-NERVE FUNCTION DURING CRANIOTOMY
    FEINSOD, M
    SELHORST, JB
    HOYT, WF
    WILSON, CB
    [J]. JOURNAL OF NEUROSURGERY, 1976, 44 (01) : 29 - 31
  • [8] Hahn J F, 1983, Clin Neurosurg, V31, P389
  • [9] A CONTACT-LENS PHOTOSTIMULATOR FOR SURGICAL MONITORING
    HARDING, GFA
    SMITH, VH
    YORKE, HC
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1987, 66 (03): : 322 - 326
  • [10] HARDING GFA, 1988, EVOKED POTENTIALS, V3, P240