VOLTAMMETRIC DETERMINATION OF DOPAMINE IN THE PRESENCE OF ASCORBIC-ACID AT OVER-OXIDIZED POLYPYRROLE INDIGO CARMINE FILM-COATED ELECTRODES

被引:46
作者
GAO, ZQ [1 ]
CHEN, BS [1 ]
ZI, MX [1 ]
机构
[1] HENAN UNIV,DEPT CHEM,KAIFENG 475001,PEOPLES R CHINA
关键词
DOPAMINE; POLYPYRROLE; INDIGO CARMINE; VOLTAMMETRY; FILM-COATED GLASSY CARBON ELECTRODE;
D O I
10.1039/an9941900459
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Over-oxidized polypyrrole films doped with indigo carmine (PPy-IC) offer substantial improvements in voltammetric sensitivity and selectivity towards dopamine. This polymer coating attenuates the voltammetric response of ascorbic acid while the oxidation peak current of dopamine is enhanced by over one order of magnitude compared with that at the bare electrode. The high sensitivity and selectivity for dopamine appears to be mainly due to the charge discrimination and the analyte accumulation. The detection limit is dependent on both film thickness and preconcentration time. At a 0.25 mum thick PPy-IC film-coated electrode, for a 2 min preconcentration time, the detection limit is 10(-8) mol 1-1, over two orders of magnitude lower than at a bare glassy carbon electrode. The concomitant ascorbic acid shows no interference although its concentration is as high as 0.1 mmol l-1. The effects of various experimental parameters on the voltammetric response of dopamine were also investigated. The attractive permselective and preconcentrating properties of the PPy-IC films make them valuable for in vivo electrochemistry.
引用
收藏
页码:459 / 464
页数:6
相关论文
共 38 条
[1]  
ABE T, 1991, ANAL CHEM, V63, P24
[2]  
ADAMS RN, 1976, ANAL CHEM, V48, P1126, DOI 10.1021/ac50007a045
[3]   ELECTROCHEMICAL ACTIVATION OF CARBON ELECTRODES IN BASE - MINIMIZATION OF DOPAMINE ADSORPTION AND ELECTRODE CAPACITANCE [J].
ANJO, DM ;
KAHR, M ;
KHODABAKHSH, MM ;
NOWINSKI, S ;
WANGER, M .
ANALYTICAL CHEMISTRY, 1989, 61 (23) :2603-2608
[4]  
Bard A., 1980, ELECTROCHEMICAL METH
[5]   ORGANIC ELECTROCHEMISTRY IN THE SOLID STATE-OVEROXIDATION OF POLYPYRROLE [J].
BECK, F ;
BRAUN, P ;
OBERST, M .
BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1987, 91 (09) :967-974
[6]   CHEMICALLY MODIFIED ELECTRODE FOR INVIVO MONITORING OF BRAIN CATECHOLAMINES [J].
BLAHA, CD ;
LANE, RF .
BRAIN RESEARCH BULLETIN, 1983, 10 (06) :861-864
[7]   DISTINGUISHING INVITRO ELECTROCHEMICAL SIGNATURES FOR NOREPINEPHRINE AND DOPAMINE [J].
BRODERICK, PA .
NEUROSCIENCE LETTERS, 1988, 95 (1-3) :275-280
[8]   STATE-OF-THE-ART MICROELECTRODES FOR INVIVO VOLTAMMETRY [J].
BRODERICK, PA .
ELECTROANALYSIS, 1990, 2 (03) :241-251
[9]   NAFION-COATED CARBON-FIBER ELECTRODES FOR NEUROCHEMICAL STUDIES IN BRAIN-TISSUE [J].
CAPELLA, P ;
GHASEMZADEH, B ;
MITCHELL, K ;
ADAMS, RN .
ELECTROANALYSIS, 1990, 2 (03) :175-182
[10]   ESTIMATION OF FREE DOPAMINE IN THE CYTOPLASM OF THE GIANT DOPAMINE CELL OF PLANORBIS-CORNEUS BY VOLTAMMETRY AND CAPILLARY ELECTROPHORESIS [J].
CHIEN, JB ;
WALLINGFORD, RA ;
EWING, AG .
JOURNAL OF NEUROCHEMISTRY, 1990, 54 (02) :633-638