TRIPLE IMMUNOFLUORESCENCE FLOW-CYTOMETRY, USING WHOLE-BLOOD, OF CD4+ AND CD8+ LYMPHOCYTES EXPRESSING CD45RO AND CD45RA

被引:33
作者
GRUBER, R
REITER, C
RIETHMULLER, G
机构
[1] Institut für Immunologie, Universität München, Munich
关键词
FLOW CYTOMETRY; 3-COLOR STAINING; LYMPHOCYTE SUBPOPULATION; CD45RO/RA;
D O I
10.1016/0022-1759(93)90120-V
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
New fluorescent monoclonal antibody-dye conjugates permit three-color immunofluorescence analysis of leukocytes in whole blood using a single laser flow cytometer. The fluorochrome used in this study is a tandem conjugate of phycoerythrin (PE) and Cyan-5, which is excitable at 488 nm with a maximum in the emission spectrum at > 650 nm and it can be used together with PE and fluorescein isothiocyanate (FITC). The directly labelled monoclonal antibodies are incubated with unseparated anticoagulated blood and subsequently erythrocytes are lysed by a standardized automated procedure. The resulting leukocyte suspension can then be analyzed for three different surface markers in an individual sample of 100 mul blood. When compared simultaneously with single-color analysis triple-color immunofluorescence yielded identical quantitative and qualitative results on various lymphocyte subpopulations. The efficacy of this method was evaluated by analyzing leukocytes of 42 healthy donors for the following markers: CD3, CD4, CD8, CD14, CD16, CD19, CD25, CD38, CD45RO, CD45RA, CD56, CD57, TCR-gamma/delta and HLA-DR. Of special interest was the finding that CD45RA and CD45RO are differently expressed in CD4 and CD8 cells. The reliability and convenience of this three-color analysis will make it possible to do more sophisticated examinations of subpopulations and their relevance in the monitoring of autoimmune diseases, immunodeficiency syndromes including AIDS and malignant disorders such as leukemias.
引用
收藏
页码:173 / 179
页数:7
相关论文
共 20 条
[1]   DETECTION OF LYMPHOCYTE SUBSETS USING 3-COLOR SINGLE-LASER FLOW-CYTOMETRY AND THE FLUORESCENT DYE PERIDININ CHLOROPHYLL-A PROTEIN [J].
AFAR, B ;
MERRILL, J ;
CLARK, EA .
JOURNAL OF CLINICAL IMMUNOLOGY, 1991, 11 (05) :254-261
[2]  
AKBAR AN, 1988, J IMMUNOL, V140, P2171
[3]   LYMPHOCYTE SUBSET ANALYSIS BY FLOW-CYTOMETRY - COMPARISON OF 3 DIFFERENT STAINING TECHNIQUES AND EFFECTS OF BLOOD-STORAGE [J].
ASHMORE, LM ;
SHOPP, GM ;
EDWARDS, BS .
JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 118 (02) :209-215
[4]   INTERCONVERSION OF CD45R SUBSETS OF CD4 T-CELLS INVIVO [J].
BELL, EB ;
SPARSHOTT, SM .
NATURE, 1990, 348 (6297) :163-166
[5]   FLOW CYTOMETRIC ANALYSIS OF IMMUNOGOLD CELL-SURFACE LABEL [J].
BOHMER, RM ;
KING, NJC .
CYTOMETRY, 1984, 5 (05) :543-546
[6]  
COON JS, 1987, LAB INVEST, V57, P453
[7]   HIGH-RESOLUTION DUAL LASER FLOW CYTOMETRY [J].
DEAN, PN ;
PINKEL, D .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1978, 26 (08) :622-627
[8]   ENUMERATION OF HUMAN-LYMPHOCYTE SUBSETS BY MONOCLONAL-ANTIBODIES AND FLOW-CYTOMETRY - A COMPARATIVE-STUDY USING WHOLE-BLOOD OR MONONUCLEAR-CELLS SEPARATED BY DENSITY GRADIENT CENTRIFUGATION [J].
DEPAOLI, P ;
REITANO, M ;
BATTISTIN, S ;
CASTIGLIA, C ;
SANTINI, G .
JOURNAL OF IMMUNOLOGICAL METHODS, 1984, 72 (02) :349-353
[9]   DETECTION OF TRIPLE ANTIBODY-BINDING LYMPHOCYTES IN STANDARD SINGLE LASER FLOW-CYTOMETRY USING COLLOIDAL GOLD, FLUORESCEIN AND PHYCOERYTHRIN AS LABELS [J].
FESTIN, R ;
BJORKLUND, B ;
TOTTERMAN, TH .
JOURNAL OF IMMUNOLOGICAL METHODS, 1987, 101 (01) :23-28
[10]   SINGLE LASER FLOW CYTOMETRIC DETECTION OF LYMPHOCYTES BINDING 3 ANTIBODIES LABELED WITH FLUORESCEIN, PHYCOERYTHRIN AND A NOVEL TANDEM FLUOROCHROME CONJUGATE [J].
FESTIN, R ;
BJORKLAND, A ;
TOTTERMAN, TH .
JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 126 (01) :69-78