SINGLE-EXPOSURE DUAL-ENERGY COMPUTED RADIOGRAPHY - IMPROVED DETECTION AND PROCESSING

被引:105
作者
ERGUN, DL
MISTRETTA, CA
BROWN, DE
BYSTRIANYK, RT
SZE, WK
KELCZ, F
NAIDICH, DP
机构
[1] UNIV WISCONSIN,MADISON,WI 53706
[2] NYU,NEW YORK,NY 10003
关键词
radiography; computer-assisted; digital; technology; screens and films; subtraction; dual-energy;
D O I
10.1148/radiology.174.1.2294555
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent reports have emphasized the potential for dual-energy computed radiographic applications. An improved method for single-exposure material-selective imaging with a photostimulable phosphor computed radiography system was investigated. The essential elements of the technique are (a) prefiltration with gadolinium, which divides the incident broad-beam x-ray spectrum into low-energy and high-energy peaks; (b) a cassette consisting of four photostimulable phosphor plates that record images of increasing mean energies, with a computed energy separation of 23 keV from the front to the rear plate; (c) spatially dependent scatter and beam-hardening corrections; and (d) a noise-reduction algorithm based on noise correlations between bone-selective and soft-tissue-selective dual-energy images. These elements result in improved material cancellation and signal-to-noise ratio throughout the image.
引用
收藏
页码:243 / 249
页数:7
相关论文
共 20 条
[1]   DETECTOR FOR DUAL-ENERGY DIGITAL RADIOGRAPHY [J].
BARNES, GT ;
SONES, RA ;
TESIC, MM ;
MORGAN, DR ;
SANDERS, JN .
RADIOLOGY, 1985, 156 (02) :537-540
[2]   LEAST-SQUARES APPROACH IN MEASUREMENT-DEPENDENT FILTERING FOR SELECTIVE MEDICAL IMAGES [J].
CAO, QZ ;
BROSNAN, T ;
MACOVSKI, A ;
NISHIMURA, D .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (02) :154-160
[3]  
ERGUN DL, 1983, THESIS U WISCONSIN M
[4]   MINERAL-CONTENT OF BONE - MEASUREMENT BY ENERGY SUBTRACTION DIGITAL CHEST RADIOGRAPHY [J].
FRIEDMAN, SE ;
DUBOVSKY, EV ;
DUBOVSKY, J ;
ALEXANDER, CB ;
ROBINSON, CA ;
SABBAGH, EA ;
BARNES, GT ;
FRASER, RG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (06) :1199-1202
[5]   DUAL-ENERGY DIGITAL RADIOGRAPHIC QUANTIFICATION OF CALCIUM IN SIMULATED PULMONARY NODULES [J].
HICKEY, NM ;
NIKLASON, LT ;
SABBAGH, E ;
FRASER, RG ;
BARNES, GT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (01) :19-24
[6]   ONE-SHOT DUAL-ENERGY SUBTRACTION CHEST IMAGING WITH COMPUTED RADIOGRAPHY - CLINICAL-EVALUATION OF FILM IMAGES [J].
ISHIGAKI, T ;
SAKUMA, S ;
IKEDA, M .
RADIOLOGY, 1988, 168 (01) :67-72
[7]   ONE-SHOT DUAL-ENERGY SUBTRACTION IMAGING [J].
ISHIGAKI, T ;
SAKUMA, S ;
HORIKAWA, Y ;
IKEDA, M ;
YAMAGUCHI, H .
RADIOLOGY, 1986, 161 (01) :271-273
[8]  
JACOBSON B, 1958, Adv Biol Med Phys, V6, P201
[9]   AN ALGORITHM FOR NOISE SUPPRESSION IN DUAL ENERGY CT MATERIAL DENSITY IMAGES [J].
KALENDER, WA ;
KLOTZ, E ;
KOSTARIDOU, L .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (03) :218-224
[10]   LESION CONSPICUITY, STRUCTURED NOISE, AND FILM READER ERROR [J].
KUNDEL, HL ;
REVESZ, G .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1976, 126 (06) :1233-1238