摘要
Back ionization from porous layers of tissue paper on the plane of a point-to-plane corona discharge has been studied by observing light emission from the layer and from the point and by detecting the associated current pulses in the external circuit. A quasi-continuous low level light emission was detected from all paper surfaces. It is proposed that this glow emanates from a discharge which is the source of a steady current of positive ions which is responsible for the increase in Trichel pulse frequency; this in turn accounts for nearly all the increase in the current in the external circuit during back ionization. Three types of pulsed light enmission were also detected. This work is relevant to electrostatic precipitation and powder coating.
引用
收藏
页码:327 / 344
页数:18
相关论文
共 18 条
  • [1] Negative ion formation and evolution in atmospheric pressure corona discharges between point-to-plane electrodes with arbitrary needle angle
    Sekimoto, K.
    Takayama, M.
    EUROPEAN PHYSICAL JOURNAL D, 2010, 60 (03) : 589 - 599
  • [2] MICROWAVE BREAKDOWN IN A POINT-TO-PLANE ELECTRODE-GAP
    EXCELL, PS
    IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1992, 139 (03): : 89 - 97
  • [3] Numerical Investigation of Negative Corona Discharge From Protrusion on Parallel Plane Electrodes in Air Insulation
    Fahmi, Daniar
    Illias, Hazlee Azil
    Mokhlis, Hazlie
    Negara, I. M. Yulistya
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2022, 50 (10) : 3830 - 3838
  • [4] Theoretical investigation of ozone production in negative corona discharge
    Mennad, B.
    Harrache, Z.
    Aid, D. Amir
    Belasri, A.
    CURRENT APPLIED PHYSICS, 2010, 10 (06) : 1391 - 1401
  • [5] Ionization and charge transport phenomena in liquid helium induced by corona discharge
    Li, Z.
    Bonifaci, N.
    Denat, A.
    Atrazhev, V. M.
    Atrazhev, V. V.
    JOURNAL OF ELECTROSTATICS, 2008, 66 (5-6) : 263 - 274
  • [6] Interaction between negative corona discharge and vapour condensation in steam jets
    Zhan, Wei
    Yang, Lanjun
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2025, 58 (22)
  • [7] Study of the Effects of Alternating Magnetic Field on Point-plane Corona
    Bhangaonkar, Avinash S.
    Kulkarni, S. V.
    Shevgaonkar, R. K.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (06) : 1813 - 1820
  • [8] Numerical Study of Negative Corona Discharge Characteristics at Different Electrode Gap Spacing
    Feng, Qi-Kun
    Zhong, Shao-Long
    Zheng, Ming-Sheng
    Dang, Zhi-Min
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2020, 48 (08) : 2831 - 2836
  • [9] On the Potential Impacts of Extreme Low Temperature on Threshold Inception Characteristics of Negative Corona Discharge
    Yi, Yong
    Tang, Wenxi
    Wang, Liming
    Li, Chuanyang
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2020, 48 (12) : 4071 - 4079
  • [10] Performance evaluation of oxygen adsorbents using negative corona discharge-ion mobility spectrometry
    Azadkish, Kamal
    Jafari, Mohammad T.
    Ghaziaskar, Hassan S.
    ANALYTICA CHIMICA ACTA, 2017, 953 : 32 - 39