Quantitative evaluation of dual-flip-angle T-1 mapping on DCE-MRI kinetic parameter estimation in head and neck

被引:41
作者
Yuan, Jing [1 ]
Chow, Steven Kwok Keung [1 ]
Yeung, David Ka Wai [1 ]
Ahuja, Anil T. [1 ]
King, Ann D. [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Imaging & Intervent Radiol, Shatin, Hong Kong, Peoples R China
关键词
DCE-MRI; head and neck; Tofts model; T-1; mapping; dual-flip-angle method;
D O I
10.3978/j.issn.2223-4292.2012.11.04
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To quantitatively evaluate the kinetic parameter estimation for head and neck (HN) dynamic contrast-enhanced (DCE) MRI with dual-flip-angle (DFA) T-1 mapping. Materials and methods: Clinical DCE-MRI datasets of 23 patients with HN tumors were included in this study. T-1 maps were generated based on multiple-flip-angle (MFA) method and different DFA combinations. Tofts model parameter maps of k(ep), K-trans and v(p) based on MFA and DFAs were calculated and compared. Fitted parameter by MFA and DFAs were quantitatively evaluated in primary tumor, salivary gland and muscle. Results: T-1 mapping deviations by DFAs produced remarkable kinetic parameter estimation deviations in head and neck tissues. In particular, the DFA of [2 degrees, 7 degrees] overestimated, while [7 degrees, 12 degrees] and [7 degrees, 15 degrees] underestimated K-trans and v(p), significantly (P<0.01). [2 degrees, 15 degrees] achieved the smallest but still statistically significant overestimation for K-trans and v(p) in primary tumors, 32.1% and 16.2% respectively. k(ep) fitting results by DFAs were relatively close to the MFA reference compared to K-trans and v(p). Conclusions: T-1 deviations induced by DFA could result in significant errors in kinetic parameter estimation, particularly Ktrans and vp, through Tofts model fitting. MFA method should be more reliable and robust for accurate quantitative pharmacokinetic analysis in head and neck.
引用
收藏
页码:245 / 253
页数:9
相关论文
共 41 条
[1]   Delayed Gadolinium-enhanced MR Imaging of Articular Cartilage: Three-dimensional T1 Mapping with Variable Flip Angles and B1 Correction [J].
Andreisek, Gustav ;
White, Lawrence M. ;
Yang, Yi ;
Robinson, Emma ;
Cheng, Hai-Ling Margaret ;
Sussman, Marshall S. .
RADIOLOGY, 2009, 252 (03) :865-873
[2]   An exploratory pilot study into the association between microcirculatory parameters derived by MRI-based pharmacokinetic analysis and glucose utilization estimated by PET-CT imaging in head and neck cancer [J].
Bisdas, Sotirios ;
Seitz, Oliver ;
Middendorp, Markus ;
Chambron-Pinho, Nicole ;
Bisdas, Theodosios ;
Vogl, Thomas J. ;
Hammerstingl, Renate ;
Ernemann, Ulrike ;
Mack, Martin G. .
EUROPEAN RADIOLOGY, 2010, 20 (10) :2358-2366
[3]   PHARMACOKINETIC PARAMETERS IN CNS GD-DTPA ENHANCED MR IMAGING [J].
BRIX, G ;
SEMMLER, W ;
PORT, R ;
SCHAD, LR ;
LAYER, G ;
LORENZ, WJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) :621-628
[4]   Measurement of spin-lattice relaxation times with FLASH for dynamic MRI of the breast [J].
Brookes, JA ;
Redpath, TW ;
Gilbert, FJ ;
Needham, G ;
Murray, AD .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (819) :206-214
[5]  
Brookes JA, 1999, JMRI-J MAGN RESON IM, V9, P163, DOI 10.1002/(SICI)1522-2586(199902)9:2<163::AID-JMRI3>3.0.CO
[6]  
2-L
[7]   Dynamic contrast enhanced-MRI in head and neck cancer patients: Variability of the precontrast longitudinal relaxation time (T10) [J].
Craciunescu, Oana ;
Brizel, David ;
Cleland, Esi ;
Yoo, David ;
Muradyan, Naira ;
Carroll, Madeline ;
Barboriak, Daniel ;
MacFall, James .
MEDICAL PHYSICS, 2010, 37 (06) :2683-2692
[8]   Improvement in breast lesion characterization with dynamic contrast-enhanced MRI using pharmacokinetic modeling and bookend T1 measurements [J].
Cron, GO ;
Kelcz, F ;
Santyr, GE .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) :1066-1070
[9]   Flip angle optimization for dynamic contrast-enhanced MRI-studies with spoiled gradient echo pulse sequences [J].
De Naeyer, D. ;
Verhulst, J. ;
Ceelen, W. ;
Segers, P. ;
De Deene, Y. ;
Verdonck, P. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16) :5373-5395
[10]   Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state [J].
Deoni, SCL ;
Rutt, BK ;
Peters, TM .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) :515-526