Biomechanical issues of practical relevance to the physician in the clinical management of patients undergoing endovascular repair (EVR) of their abdominal aortic aneurysms (AAA) is discussed. Following a brief description of key terms in vascular biomechanics, background on the current state of knowledge in the biomechanics of AAA pathogenesis and rupture is provided. This is followed by a discussion of key issues of biomechanical relevance in EVR such as the mechanics of endotension, the notion of intraaneurysmal sac pressure and potential pitfalls of techniques used to measure them, mechanics of graft fracture/kinking, and graft migration. The discussions are intended to provide an overview of this field to physicians. Tech Vasc Interventional Rad 8: 50-55 (C) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:50 / 55
页数:6
相关论文
共 31 条
  • [1] Intrasac pressure waveforms after endovascular aneurysm repair (EVAR) are a reliable marker of type I endoleaks, but not type II or combined types: An experimental study
    Chaudhuri, A
    Ansdell, LE
    Grass, AJ
    Adiseshiah, M
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2004, 28 (04) : 373 - 378
  • [2] Fluid-structure interaction within realistic three-dimensional models of the aneurysmatic aorta as a guidance to assess the risk of rupture of the aneurysm
    Di Martino, ES
    Guadagni, G
    Fumero, A
    Ballerini, G
    Spirito, R
    Biglioli, P
    Redaelli, A
    [J]. MEDICAL ENGINEERING & PHYSICS, 2001, 23 (09) : 647 - 655
  • [3] Intra-aneurysm sac pressure measurements after endovascular aneurysm repair: Differences between shrinking, unchanged, and expanding aneurysms with and without endoleaks
    Dias, NV
    Ivancev, K
    Malina, M
    Resch, T
    Lindblad, B
    Sonesson, B
    [J]. JOURNAL OF VASCULAR SURGERY, 2004, 39 (06) : 1229 - 1235
  • [4] DIMARTINO E, 2004, INT MECH ENG C EXP A
  • [5] Dubenec SR, 2003, J CARDIOVASC SURG, V44, P553
  • [6] First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms
    Ellozy, SH
    Carroccio, A
    Lookstein, RA
    Minor, ME
    Sheahan, CM
    Juta, J
    Cha, A
    Valenzuela, R
    Addis, MD
    Jacobs, MS
    Teodorescu, VJ
    Marin, ML
    [J]. JOURNAL OF VASCULAR SURGERY, 2004, 40 (03) : 405 - 411
  • [7] Prediction of rupture risk in abdominal aortic aneurysm during observation: Wall stress versus diameter
    Fillinger, MF
    Marra, SP
    Raghavan, ML
    Kennedy, FE
    [J]. JOURNAL OF VASCULAR SURGERY, 2003, 37 (04) : 724 - 732
  • [8] In vivo analysis of mechanical wall stress and abdominal aortic aneurysm rupture risk
    Fillinger, MF
    Raghavan, ML
    Marra, SP
    Cronenwett, JL
    Kennedy, FE
    [J]. JOURNAL OF VASCULAR SURGERY, 2002, 36 (03) : 589 - 597
  • [9] The effect of asymmetry in abdominal aortic aneurysms under physiologically realistic pulsatile flow conditions
    Finol, EA
    Keyhani, K
    Amon, CH
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (02): : 207 - 217
  • [10] Endotension as a result of pressure transmission through the graft following endovascular aneurysm repair - An in vitro study
    Gawenda, M
    Jaschke, G
    Winter, S
    Wassmer, G
    Brunkwall, J
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2003, 26 (05) : 501 - 505