Optimization of unilateral molar rotation correction by a trans-palatal bar: a three-dimensional analysis using the finite element method

被引:1
作者
Geramy, Allahyar [1 ]
Etezadi, Tahura [1 ]
机构
[1] Univ Tehran Med Sci, Orthodont Dept, Tehran, Iran
关键词
Asymmetric activation; finite element method; rotation; transpalatal bar; unilateral;
D O I
10.1179/1465313313Y.0000000050
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The main goal of this study was to optimize unilateral molar rotation correction by modifying a trans-palatal arch (TPA) design using the finite element method. Design: Three-dimensional analysis of different TPA designs was carried out using the finite element method. Setting: Department of Orthodontics, Tehran University of Medical Sciences, Iran. Material and methods: For this investigation, 13 three-dimensional finite element models were produced for different TPA designs without pre-activation bends. Each model contained a palatal bar and two tubes. Optimizing unilateral molar rotations was achieved by five separate different paths: incorporating U-loop(s), 'R' loop(s) or helix/helices, a reverse action of the helix/helices and adding a straight wire to the design. The mesial part of the left side tube was displaced 0.1, 0.25, 0.5 and 1 mm, successively towards the midline, simulating palatal bar tab engagement in a mesio-palatal rotated maxillary left molar. The mesio-distal force, moment and energy produced in the normal side (right) molar were recorded for each of the models. Results: Findings showed that in all designs, the associated mesializing force was lower than that seen in the traditional design and the moment showed an increasing pattern when compared with a simple palatal bar. Regarding energy levels, the same increasing pattern was observed in the designs between activations of 0.1 and 1.0 mm. Conclusion: According to our optimized system, the TPA design with the highest energy and moment, but the lowest mesializing force associated with derotating a maxillary molar tooth was a parallel wire II design (i.e. adding a straight wire).
引用
收藏
页码:197 / 205
页数:9
相关论文
共 23 条
[1]  
[Anonymous], 1999, SPRINGER SCI
[3]  
Bench R W, 1998, Semin Orthod, V4, P231, DOI 10.1016/S1073-8746(98)80028-5
[4]   Stress-related molar responses to the transpalatal arch: A finite element analysis [J].
Bobak, V ;
Christiansen, RL ;
Hollister, SJ ;
Kohn, DH .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1997, 112 (05) :512-518
[5]  
BURSTONE CJ, 1981, AM J ORTHOD DENTOFAC, V79, P115, DOI 10.1016/0002-9416(81)90310-9
[6]   Tongue pressure on loop of transpalatal arch during deglutition [J].
Chiba, Y ;
Motoyoshi, M ;
Namura, S .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2003, 123 (01) :29-34
[7]  
Dahlquist A, 1996, EUR J ORTHODONT, V18, P257
[8]   Alveolar bone resorption and the center of resistance modification - (3-D analysis by means of the finite element method) [J].
Geramy, A .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2000, 117 (04) :399-405
[9]  
Geramy A, 2003, QUINTESSENCE INT, V34, P526
[10]  
Geramy A, 2002, ANGLE ORTHOD, V72, P585