COMPARISON OF 6 FILES TO PREPARE SIMULATED ROOT CANALS .2.

被引:49
|
作者
ALOMARI, MAO [1 ]
DUMMER, PMH [1 ]
NEWCOMBE, RG [1 ]
DOLLER, R [1 ]
HARTLES, F [1 ]
机构
[1] UNIV WALES COLL CARDIFF,COLL MED,SCH DENT,DEPT CONSERVAT DENT,HEATH PK,CARDIFF CF4 4XY,WALES
关键词
ENDODONTICS; FILES; ROOT CANALS; SHAPING;
D O I
10.1111/j.1365-2591.1992.tb00739.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A total of 300 simulated root canals of various angles and positions of curvature in clear resin blocks were prepared by hand using either K-files, K-Flex files, Flexofiles, Flex-R files, Hedstrom files or Unifiles. Each file type was used to prepare 50 canals employing a linear filing motion and an anticurvature stepback technique. Part 2 of this two-part report describes the efficacy of the files in terms of the prevalence of canal aberrations, the amount and direction of canal transportation and the overall postoperative canal shape. Hourglass shaped canals were found in 4.5% of curved canals, the majority of these being created by K-files and K-Flex files. Perforations were seen in 6.3% of curved canals, the majority being produced by Flex-R files and K-files. Excessive removal of material from along the inner aspect of the canal curve occurred in 10.4% of canals, by far the majority being created by Hedstrom files. Transportation of canals was a consistent finding with all instruments. Two-way analysis of variance revealed how significant differences in the absolute magnitude of transportation occurred between instruments, between canal types and by an interaction between instrument and canal type. in general, transportation was towards the outer aspect of the canal curve at the end-point of preparation and the zip and elbow, but towards the inner aspect at the beginning of the curve. Further towards the orifice, transportation reverted to the outer aspect of the canal curve. In straight canals, one-way analysis of variance indicated that significant differences (P < 0.05) occurred in the width of canals at their end-point between instruments. In curved canals, two-way analysis of variance indicated that the width of canals throughout their length varied significantly between instruments, between canal types and in some instances with interaction between instrument and canal type. Under the conditions of this study, canal shaping with Flexofiles and Flex-R files appeared to be superior to that possible with K-files, K-Flex files, Hedstrom files or Unifiles.
引用
收藏
页码:67 / 81
页数:15
相关论文
共 50 条
  • [21] Root canal transportation with a Ni-Ti rotary file system and stainless steel hand files in simulated root canals
    Loizides, Alexios
    Eliopoulos, Dimitris
    Kontakiotis, Evangelos
    QUINTESSENCE INTERNATIONAL, 2006, 37 (05): : 369 - 374
  • [22] Electrochemical induced dissolution of fragments of nickel-titanium endodontic files and their removal from simulated root canals
    Aboud, L. R. L.
    Ormiga, F.
    Gomes, J. A. C. P.
    INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (02) : 155 - 162
  • [23] A comparison of stainless steel and nickel-titanium K-files in curved root canals
    Chan, AWK
    Cheung, GSP
    INTERNATIONAL ENDODONTIC JOURNAL, 1996, 29 (06) : 370 - 375
  • [24] Comparison of the Efficacy of NeoNiTi, ProTaper, and Reciproc Files in the Retreatment of Curved Root Canals: a CBCT Assessment
    Adel, Mamak
    Tofangchiha, Maryam
    Rashvand, Ensiyeh
    Moutabha, Iman
    Roohi, Neda
    Reda, Rodolfo
    Testarelli, Luca
    ACTA STOMATOLOGICA CROATICA, 2022, 56 (04) : 351 - 362
  • [25] Shaping ability of lightspeed rotary nickel-titanium instruments in simulated root canals. 2.
    Thompson, SA
    Dummer, PMH
    JOURNAL OF ENDODONTICS, 1997, 23 (12) : 742 - 747
  • [26] Comparison of the shaping ability of Twisted Files with ProTaper and RevoS nickel-titanium instruments in simulated canals
    Aydin, Cumhur
    Inan, Ugur
    Gultekin, Murside
    JOURNAL OF DENTAL SCIENCES, 2012, 7 (03) : 283 - 288
  • [27] Comparison of shaping ability of ProTaper Next and 2Shape nickel-titanium files in simulated severe curved canals
    Staffoli, Simone
    Ozyurek, Taha
    Hadad, Avi
    Lvovsky, Alex
    Solomonov, Michael
    Azizi, Hadas
    Ben Itzhak, Joe
    Bossu, Maurizo
    Grande, Nicola M.
    Plotino, Gianluca
    Polimeni, Antonella
    GIORNALE ITALIANO DI ENDODONZIA, 2018, 32 (02): : 52 - 56
  • [28] A comparison of stainless steel Flexofiles and nickel-titanium NiTiFlex files during the shaping of simulated canals
    Bishop, K
    Dummer, PMH
    INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) : 25 - 34
  • [29] Comparison of Flex-R and Pow-R Files during the shaping of simulated canals.
    Zucco, L
    Manfro, A
    Dummer, P
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1122 - 1122
  • [30] DEVELOPMENT OF A MECHANICAL ROOT SHAPING INSTRUMENT .2. ROOT SUBSTANCE REMOVAL OF THE ROOTHSHAPE(R) FILES IN COMPARISON TO CURETTES
    HUGO, B