Efficacy of regional saturation of oxygen monitor using near-infrared spectroscopy for lower limb ischemia during minimally invasive cardiac surgery

被引:0
作者
Teppei Toya
Tomoyuki Fujita
Satuki Fukushima
Yusuke Shimahara
Yuta Kume
Kizuku Yamashita
Yorihiko Matsumoto
Naonori Kawamoto
Junjiro Kobayashi
机构
[1] National Cerebral and Cardiovascular Center,Department of Cardiac Surgery
来源
Journal of Artificial Organs | 2018年 / 21卷
关键词
Near-infrared spectroscopy; Regional saturation of oxygen; Minimally invasive cardiac surgery; Lower limb ischemia;
D O I
暂无
中图分类号
学科分类号
摘要
Lower limb ischemia with an occlusive cannula is a potential complication of minimally invasive cardiac surgery (MICS). We evaluated intraoperative local oxygen supply–demand balance by monitoring regional saturation of oxygen (rSO2) using near-infrared spectroscopy (NIRS), and analyzed the correlation between cannula size and fluctuation range of rSO2. Fifty-four patients undergoing MICS surgery using femoral artery cannulation from April 2015 to August 2016 were enrolled. The rSO2 of both the cannulated and uncannulated lower limbs were measured using NIRS. The association between the decline of rSO2 from baseline (delta-rSO2) and the ratio of the cannula diameter to the femoral artery diameter (Cd/FAd) was analyzed. Of the 54 patients, 16 (30%) (Group 1) showed values over 0.65 for Cd/FAd, and the remaining 38 (70%) (Group 2) showed values under 0.65. No patient developed postoperative lower limb ischemia. No patient was treated with an ipsilateral distal perfusion cannula. There were significant differences between Group 1 and Group 2 in the decrease of rSO2 at the point of cannulation on the cannulated limb. In the lower limb on the cannulated side, delta-rSO2 showed a significant decrease in Group 1 compared to Group 2 (Group 1 vs Group 2: 19.9 vs 11.0%; p < 0.001). Delta-rSO2 was significantly correlated with body surface aera (BSA), but not with gender or age. Decreasing rSO2 correlates with the Cd/FAd index. Low BSA, Cd/Fad > 0.65 is considered as the risk factor for decline of rSO2 in cannulated limb in MICS.
引用
收藏
页码:420 / 426
页数:6
相关论文
共 57 条
[1]  
Glower DD(1998)Mitral valve operation via port-access versus median sternotomy Eur J Cardiothorac Surg 14 143-147
[2]  
Landolfo KP(2012)Evolution of operative techniques and perfusion strategies for minimally invasive mitral valve repair J Thorac Cardiovasc Surg 143 68-70
[3]  
Clements F(2010)Limb ischemia after common femoral artery cannulation for venoarterial extracorporeal membrane oxygenation: an unresolved problem J Pediatr Surg 45 2136-2140
[4]  
Grossi EA(2011)Vascular complications in patients undergoing femoral cannulation for extracorporeal membrane oxygenation support Ann Thorac Surg 92 626-631
[5]  
Loulmet DF(1996)Thigh ischemia complicating femoral vessel cannulation for cardiopulmonary bypass Ann Thorac Surg 61 730-733
[6]  
Schwartz CF(2006)A simple technique of distal limb perfusion during prolonged femorofemoral cannulation J Card Surg 21 168-169
[7]  
Gander JW(1999)The prevention of leg ischemia during femoral cannulation Ann Thorac Surg 67 1217-204
[8]  
Fisher JC(1986)In vitro comparison of cavoatrial (dual stage) cannulae for use during cardiopulmonary bypass Perfusion 1 197-281
[9]  
Reichstein AR(1992)A new method for describing the performance of cardiac surgery cannulas Ann Thorac Surg 33 278-428
[10]  
Bisdas T(2002)Technique to prevent limb ischemia during peripheral cannulation for extracorporeal membrane oxygenation Perfusion 17 427-726