Overoptimism in cross-validation when using partial least squares-discriminant analysis for omics data: a systematic study

被引:0
|
作者
Raquel Rodríguez-Pérez
Luis Fernández
Santiago Marco
机构
[1] The Barcelona Institute for Science and Technology,Signal and Information Processing for Sensing Systems, Institute for Bioengineering of Catalonia
[2] University of Barcelona,Department of Electronics and Biomedical Engineering
来源
Analytical and Bioanalytical Chemistry | 2018年 / 410卷
关键词
Metabolomics; Mass spectrometry; Microarrays; Chemometrics; Data analysis; Classification; Method validation;
D O I
暂无
中图分类号
学科分类号
摘要
Advances in analytical instrumentation have provided the possibility of examining thousands of genes, peptides, or metabolites in parallel. However, the cost and time-consuming data acquisition process causes a generalized lack of samples. From a data analysis perspective, omics data are characterized by high dimensionality and small sample counts. In many scenarios, the analytical aim is to differentiate between two different conditions or classes combining an analytical method plus a tailored qualitative predictive model using available examples collected in a dataset. For this purpose, partial least squares-discriminant analysis (PLS-DA) is frequently employed in omics research. Recently, there has been growing concern about the uncritical use of this method, since it is prone to overfitting and may aggravate problems of false discoveries. In many applications involving a small number of subjects or samples, predictive model performance estimation is only based on cross-validation (CV) results with a strong preference for reporting results using leave one out (LOO). The combination of PLS-DA for high dimensionality data and small sample conditions, together with a weak validation methodology is a recipe for unreliable estimations of model performance. In this work, we present a systematic study about the impact of the dataset size, the dimensionality, and the CV technique used on PLS-DA overoptimism when performance estimation is done in cross-validation. Firstly, by using synthetic data generated from a same probability distribution and with assigned random binary labels, we have obtained a dataset where the true classification rate (CR) is 50%. As expected, our results confirm that internal validation provides overoptimistic estimations of the classification accuracy (i.e., overfitting). We have characterized the CR estimator in terms of bias and variance depending on the internal CV technique used and sample to dimensionality ratio. In small sample conditions, due to the large bias and variance of the estimator, the occurrence of extremely good CRs is common. We have found that overfitting peaks when the sample size in the training subset approaches the feature vector dimensionality minus one. In these conditions, the models are neither under- or overdetermined with a unique solution. This effect is particularly intense for LOO and peaks higher in small sample conditions. Overoptimism is decreased beyond this point where the abundance of noisy produces a regularization effect leading to less complex models. In terms of overfitting, our study ranks CV methods as follows: Bootstrap produces the most accurate estimator of the CR, followed by bootstrapped Latin partitions, random subsampling, K-Fold, and finally, the very popular LOO provides the worst results. Simulation results are further confirmed in real datasets from mass spectrometry and microarrays.
引用
收藏
页码:5981 / 5992
页数:11
相关论文
共 50 条
  • [31] Determination of ethyl glucuronide (EtG) in blood samples using partial least squares discriminant analysis applied to surface-enhanced Raman spectroscopy
    Acikgoz, Gunes
    Hamamci, Berna
    VIBRATIONAL SPECTROSCOPY, 2020, 106
  • [32] A Partial Least Squares Algorithm for Microarray Data Analysis Using the VIP Statistic for Gene Selection and Binary Classification
    Burguillo, Francisco J.
    Corchete, Luis A.
    Martin, Javier
    Barrera, Inmaculada
    Bardsley, William G.
    CURRENT BIOINFORMATICS, 2014, 9 (03) : 348 - 359
  • [33] Potential biomonitoring of atmospheric carbon dioxide in Coffea arabica leaves using near-infrared spectroscopy and partial least squares discriminant analysis
    Cláudia Domiciano Tormena
    Gustavo Galo Marcheafave
    Elis Daiane Pauli
    Roy Edward Bruns
    Ieda Spacino Scarminio
    Environmental Science and Pollution Research, 2019, 26 : 30356 - 30364
  • [34] Potential biomonitoring of atmospheric carbon dioxide in Coffea arabica leaves using near-infrared spectroscopy and partial least squares discriminant analysis
    Tormena, Claudia Domiciano
    Marcheafave, Gustavo Galo
    Pauli, Elis Daiane
    Bruns, Roy Edward
    Scarminio, Ieda Spacino
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2019, 26 (29) : 30356 - 30364
  • [35] Detection Method of Falsified Medicines by Using a Low-Cost Raman Scattering Spectrometer Combined with Soft Independent Modeling of Class Analogy and Partial Least Squares Discriminant Analysis
    Sanada, Tomoko
    Yoshida, Naoko
    Kimura, Kazuko
    Tsuboi, Hirohito
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2021, 44 (05) : 691 - 700
  • [36] CHARACTERIZATION AND ANALYSIS OF SOILS USING MIDINFRARED PARTIAL LEAST-SQUARES .2. CORRELATIONS WITH SOME LABORATORY DATA
    JANIK, LJ
    SKJEMSTAD, JO
    AUSTRALIAN JOURNAL OF SOIL RESEARCH, 1995, 33 (04): : 637 - 650
  • [37] Comparative investigation of partial least squares discriminant analysis and support vector machines for geological cuttings identification using laser-induced breakdown spectroscopy
    Tian, Ye
    Wang, Zhennan
    Han, Xiaoshuang
    Hou, Huaming
    Zheng, Ronger
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 102 : 52 - 57
  • [38] Use of partial least squares discriminant analysis on visible-near infrared multispectral image data to examine germination ability and germ length in spinach seeds
    Shetty, Nisha
    Olesen, Merete Halkjaer
    Gislum, Rene
    Deleuran, Lise Christina
    Boelt, Birte
    JOURNAL OF CHEMOMETRICS, 2012, 26 (8-9) : 462 - 466
  • [39] Soil type recognition as improved by genetic algorithm-based variable selection using near infrared spectroscopy and partial least squares discriminant analysis
    Xie, Hongtu
    Zhao, Jinsong
    Wang, Qiubing
    Sui, Yueyu
    Wang, Jingkuan
    Yang, Xueming
    Zhang, Xudong
    Liang, Chao
    SCIENTIFIC REPORTS, 2015, 5
  • [40] Data preprocessing and partial least squares regression analysis for reagentless determination of hemoglobin concentrations using conventional and total transmission spectroscopy
    Kim, YJ
    Kim, S
    Kim, JW
    Yoon, G
    JOURNAL OF BIOMEDICAL OPTICS, 2001, 6 (02) : 177 - 182