In-Situ Systematic Error Correction for Digital Volume Correlation Using a Reference Sample

被引:0
|
作者
B. Wang
B. Pan
G. Lubineau
机构
[1] Beihang University,Institute of Solid Mechanics
[2] King Abdullah University of Science and Technology (KAUST),Physical Science and Engineering Division, COHMAS laboratory
来源
Experimental Mechanics | 2018年 / 58卷
关键词
Digital volume correlation; Self-heating effect; Systematic error; Reference sample compensation;
D O I
暂无
中图分类号
学科分类号
摘要
The self-heating effect of a laboratory X-ray computed tomography (CT) scanner causes slight change in its imaging geometry, which induces translation and dilatation (i.e., artificial displacement and strain) in reconstructed volume images recorded at different times. To realize high-accuracy internal full-field deformation measurements using digital volume correlation (DVC), these artificial displacements and strains associated with unstable CT imaging must be eliminated. In this work, an effective and easily implemented reference sample compensation (RSC) method is proposed for in-situ systematic error correction in DVC. The proposed method utilizes a stationary reference sample, which is placed beside the test sample to record the artificial displacement fields caused by the self-heating effect of CT scanners. The detected displacement fields are then fitted by a parametric polynomial model, which is used to remove the unwanted artificial deformations in the test sample. Rescan tests of a stationary sample and real uniaxial compression tests performed on copper foam specimens demonstrate the accuracy, efficacy, and practicality of the presented RSC method.
引用
收藏
页码:427 / 436
页数:9
相关论文
共 50 条
  • [1] In-Situ Systematic Error Correction for Digital Volume Correlation Using a Reference Sample
    Wang, B.
    Pan, B.
    Lubineau, G.
    EXPERIMENTAL MECHANICS, 2018, 58 (03) : 427 - 436
  • [2] Characterization of the bone-metal implant interface by Digital Volume Correlation of in-situ loading using neutron tomography
    Le Cann, Sophie
    Tudisco, Erika
    Perdikouri, Christina
    Belfrage, Ola
    Kaestner, Anders
    Hall, Stephen
    Tagil, Magnus
    Isaksson, Hanna
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 75 : 271 - 278
  • [3] Thermal error analysis and compensation for digital image/volume correlation
    Pan, Bing
    OPTICS AND LASERS IN ENGINEERING, 2018, 101 : 1 - 15
  • [4] Internal Deformation Measurement of Polymer Bonded Sugar in Compression by Digital Volume Correlation of In-situ Tomography
    Z. Hu
    H. Luo
    S. G. Bardenhagen
    C. R. Siviour
    R. W. Armstrong
    H. Lu
    Experimental Mechanics, 2015, 55 : 289 - 300
  • [5] Internal Deformation Measurement of Polymer Bonded Sugar in Compression by Digital Volume Correlation of In-situ Tomography
    Hu, Z.
    Luo, H.
    Bardenhagen, S. G.
    Siviour, C. R.
    Armstrong, R. W.
    Lu, H.
    EXPERIMENTAL MECHANICS, 2015, 55 (01) : 289 - 300
  • [6] Digital volume correlation for meso/micro in-situ damage analysis in carbon fiber reinforced composites
    Mehdikhani, Mahoor
    Breite, Christian
    Swolfs, Yentl
    Soete, Jeroen
    Wevers, Martine
    Lomov, Stepan V.
    Gorbatikh, Larissa
    COMPOSITES SCIENCE AND TECHNOLOGY, 2021, 213
  • [7] Expanded digital volume correlation for ex situ applications
    Wan, Keshu
    Yang, Peng
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (09)
  • [8] Debonding analysis via digital volume correlation during in-situ pull-out tests on fractal fibers
    Jaenicke, G.
    Vintache, A.
    Smaniotto, B.
    Fau, A.
    Farina, I
    Fraternali, F.
    Hild, F.
    COMPOSITES PART C: OPEN ACCESS, 2022, 9
  • [9] Study of Microstructural Evolution and Strain Analysis in SiOx/C Negative Electrodes Using In-situ X-ray Tomography and Digital Volume Correlation
    Valisammagari, Abhilash
    Lachambre, Joel
    Adrien, Jerome
    Broche, Ludovic
    Petit, Martin
    Esnault, Vivien
    Maire, Eric
    BATTERIES & SUPERCAPS, 2025, 8 (02)
  • [10] In-situ Analysis of Laminated Composite Materials by X-ray Micro-Computed Tomography and Digital Volume Correlation
    R. Brault
    A. Germaneau
    J. C. Dupré
    P. Doumalin
    S. Mistou
    M. Fazzini
    Experimental Mechanics, 2013, 53 : 1143 - 1151