Development and application of a high-performance liquid chromatography diode-array detection (HPLC–DAD) method for the simultaneous quantification of phenolic compounds in the aerial part of Glehnia littoralis

被引:0
|
作者
Yun Ji Park
Yeong Bin Choi
Sang-Bin Oh
Jinyoung Moon
To Quyen Truong
Phuong Kim Huynh
Sang Min Kim
机构
[1] Gangneung Institute of Natural Products,Smart Farm Research Center, Korea Institute of Science and Technology (KIST)
[2] University of Science and Technology,Department of Bio
来源
Applied Biological Chemistry | / 67卷
关键词
High-performance liquid chromatography; Diode-array detection; Phenolic compound; Antioxidant activity;
D O I
暂无
中图分类号
学科分类号
摘要
Glehnia littoralis, a medicinal herb employed in traditional practices for alleviating fatigue, cough, and a dry throat, is recognized for its beneficial properties due to a diverse array of active compounds found in its extracts. For example, the G. littoralis roots (Radix Glehniae) mainly contain coumarins and phenolic acids, serving as the primary focus of this study. Despite the widespread use of the tools in various industries and the development of multiple analytical methods for their examination, the edible aerial parts have industrial potential, and there is currently no analytical method available to identify their key components. In this study, a high-performance liquid chromatography method combined with diode array detection (HPLC–DAD) was developed to simultaneously detect 16 phenolic compounds previously reported to be present in the edible aerial parts of G. littoralis. The proposed approach included using gradient elution to change the solvent system from water/acetonitrile to water/methanol. Furthermore, the method validation was conducted, assessing its linearity, limit of detection, limit of quantification, precision, accuracy, and recovery, all of which demonstrated satisfactory results. Subsequently, the developed method was applied to quantify the phenolic compounds in various G. littoralis samples obtained from different organs, solvent extraction processes, and processing methods. Moreover, the online HPLC-ABTS (2,2ʹ-azino-bis(3-ethylbenzthiazoline-6-sulfonic acid) assay was used to evaluate the antioxidant capacities of individual constituents, identifying four important antioxidants and estimate the overall antioxidant capacity of the G. littoralis extract.
引用
收藏
相关论文
共 50 条
  • [31] Evaluation of a method for the simultaneous quantification of N-nitrosamines in water samples based on stir bar sorptive extraction combined with high-performance liquid chromatography and diode array detection
    Talebpour, Zahra
    Rostami, Simindokht
    Rezadoost, Hassan
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (09) : 1601 - 1609
  • [32] Determination of isoflavones in soy bits by fast column high-performance liquid chromatography coupled with UV-visible diode-array detection
    Klejdus, B
    Mikelová, R
    Petrlová, J
    Potesil, D
    Adam, V
    Stiborová, M
    Hodek, P
    Vacek, J
    Kizek, R
    Kubán, V
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1084 (1-2) : 71 - 79
  • [33] Simultaneous quantification of dasatinib, nilotinib, bosutinib, and ponatinib using high-performance liquid chromatography-Photodiode array detection
    Yokoyama, Yuta
    Nozawa, Eiji
    Morita, Miho
    Ishikawa, Emi
    Mori, Takehiko
    Sakurai, Masatoshi
    Kikuchi, Taku
    Matsuki, Eri
    Yamazaki, Rie
    Kataoka, Keisuke
    Jibiki, Aya
    Kawazoe, Hitoshi
    Suzuki, Sayo
    Nakamura, Tomonori
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2022, 36 (08)
  • [34] Simultaneous determination of water- and fat-soluble vitamins in pharmaceutical preparations by high-performance liquid chromatography coupled with diode array detection
    Klejdus, B
    Petrlová, J
    Potesil, D
    Adam, V
    Mikelová, R
    Vacek, J
    Kizek, R
    Kubán, V
    ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) : 57 - 67
  • [35] Phytochemical Profiling and Evaluation of the Hepatoprotective Effect of Cuscuta Campestris by High-Performance Liquid Chromatography with Diode Array Detection
    Selvi, Emine Kilickaya
    Turumtay, Halbay
    Demir, Adem
    Turumtay, Emine Akyuz
    ANALYTICAL LETTERS, 2018, 51 (10) : 1464 - 1478
  • [36] Rapid quantitative analysis of individual anthocyanin content based on high-performance liquid chromatography with diode array detection with the pH differential method
    Wang, Huayin
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (18) : 2535 - 2544
  • [37] Quality evaluation of Radix Stemonae through simultaneous quantification of bioactive alkaloids by high-performance liquid chromatography coupled with diode array and evaporative light scattering detectors
    Li, Song-Lin
    Jiang, Ren-Wang
    Hon, Po-Ming
    Cheng, Ling
    Xu, Hong-Xi
    Greger, Harald
    But, Paul Pui-Hay
    Shaw, Pang-Chui
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (10) : 1088 - 1094
  • [38] Application of isoabsorption plots generated by high-performance liquid chromatography with diode array detection to the development of multicomponent quantitative analysis of traditional herbal medicines
    Fang, Luo
    Yang, Guonong
    Song, Yu
    Li, Fanzhu
    Lin, Nengming
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (22) : 3245 - 3252
  • [39] Simultaneous resolution of overlapping peaks in high-performance liquid chromatography and micellar electrokinetic chromatography with diode array detection using augmented iterative target transformation factor analysis
    van Zomeren, PV
    Metting, HJ
    Coenegracht, PMJ
    de Jong, GJ
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1096 (1-2) : 165 - 176
  • [40] Determination of fourteen polyphenols in pulses by high performance liquid chromatography-diode array detection (HPLC-DAD) and correlation study with antioxidant activity and colour
    Giusti, Federica
    Caprioli, Giovanni
    Ricciutelli, Massimo
    Vittori, Sauro
    Sagratini, Gianni
    FOOD CHEMISTRY, 2017, 221 : 689 - 697