Tension band wiring versus locking plate fixation for simple, two-part Mayo 2A olecranon fractures: a comparison of post-operative outcomes, complications, reoperations and economics

被引:28
|
作者
Powell A.J. [1 ]
Farhan-Alanie O.M. [2 ]
McGraw I.W.W. [1 ]
机构
[1] Department of Trauma and Orthopaedic Surgery, Royal Alexandra Hospital, Corsebar Rd, Paisley
[2] Department of Trauma and Orthopaedic Surgery, Glasgow Royal Infirmary, Glasgow
关键词
Comparison; Locking plates; Olecranon fracture; Tension band wiring;
D O I
10.1007/s12306-018-0556-6
中图分类号
学科分类号
摘要
Purpose: Simple displaced transverse olecranon fractures are traditionally managed operatively with a tension band wire device (TBW). We compared clinical outcomes, morbidity and the cost of treatment of TBW versus pre-countered low-profile locking plates for the treatment of Mayo 2A fractures. Patient and methods: All olecranon fractures admitted to our unit between 2008 and 2014 were identified (n = 129). Patient notes and radiographs were studied from presentation to final follow-up. Patient outcomes were recorded using the QuickDASH (Disabilities of Arm, Shoulder and Hand) score. Patient demographics and nature of complications were recorded as were the rate and nature of any repeat operation. Results: Eighty-nine patients had Mayo 2A fractures (69%). Sixty-four underwent TBW (n = 48) or locking plate fixation (n = 16). The mean ages of both groups were similar at 57 (15–93) and 60 (22–80), respectively. In the TBW group, the mean post-injury QuickDASH was 12.9, compared with 15.0 for the locking plate group. There was no statistically significant difference between the outcomes for either group. Nineteen of the 48 TBW patients had complications (39.6%). Sixteen of the 48 TBW patients had reoperations (33.3%). In particular, we would highlight that 13 (27.1%) of patients treated with TBW underwent subsequent removal of metalwork for hardware irritation. There were no complications and or reoperations in the 16 patients who received locking plate fixation. Both complication and reoperation rates were statistically significantly different. Despite being initially more expensive, when the cost of reoperation for TBW group was included, locking plates were found to be on average £236.33 less per patient than for TBW. Conclusions: We suggest that locking plates are superior to TBW concerning post-operative morbidity, reoperation rate and cost for Mayo 2A fractures in contrast to previous articles. Level of evidence: Therapeutic study, III. © 2018, Istituto Ortopedico Rizzoli.
引用
收藏
页码:155 / 160
页数:5
相关论文
共 8 条
  • [1] Comparison of tension band wiring and plate fixation in Mayo type 2A olecranon fractures
    Caglar, Ceyhun
    Akcaalan, Serhat
    Ozaslan, Halil Ibrahim
    Yagar, Hilal
    Ugurlu, Mahmut
    JOINT DISEASES AND RELATED SURGERY, 2021, 32 (01) : 85 - 92
  • [2] Comparison of Tension Band Wiring and Precontoured Locking Compression Plate Fixation in Mayo Type IIA Olecranon Fractures
    Schliemann, Benedikt
    Raschke, Michael J.
    Groene, Philipp
    Weimann, Andre
    Wahnert, Dirk
    Lenschow, Simon
    Koesters, Clemens
    ACTA ORTHOPAEDICA BELGICA, 2014, 80 (01): : 106 - 111
  • [3] Biomechanical comparison of tension band wiring and plate fixation with locking screws in transverse olecranon fractures
    Midtgaard, Kaare Sourin
    Soreide, Endre
    Brattgjerd, Jan Egil
    Moatshe, Gilbert
    Madsen, Jan Erik
    Flugsrud, Gunnar B.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (06) : 1242 - 1248
  • [4] Comparison of the efficacy of the tension band wiring with eyelet wire versus anatomical locking plate fixation for the treatment of displaced olecranon fractures
    Shimura, Haruhiko
    Nimura, Akimoto
    Fujita, Koji
    Kaburagi, Hidetoshi
    JOURNAL OF ORTHOPAEDIC SURGERY, 2021, 29 (03)
  • [5] Cost Assessment of Plating Versus Tension Band Wiring Constructs for Treating Mayo Type 2A Olecranon Fractures
    Steadman, Jesse N.
    Stephens, Andrew R.
    Zhang, Chong
    Presson, Angela P.
    Kazmers, Nikolas H.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (04): : 311 - 319
  • [6] Simple and comminuted displaced olecranon fractures: a clinical comparison between tension band wiring and plate fixation techniques
    Luigi Tarallo
    Raffaele Mugnai
    Roberto Adani
    Francesco Capra
    Francesco Zambianchi
    Fabio Catani
    Archives of Orthopaedic and Trauma Surgery, 2014, 134 : 1107 - 1114
  • [7] Simple and comminuted displaced olecranon fractures: a clinical comparison between tension band wiring and plate fixation techniques
    Tarallo, Luigi
    Mugnai, Raffaele
    Adani, Roberto
    Capra, Francesco
    Zambianchi, Francesco
    Catani, Fabio
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (08) : 1107 - 1114
  • [8] Locked Tension Band Wiring for Mayo IIA Olecranon Fractures: Modified Surgical Technique and Retrospective Comparative Study of Clinical Outcomes and Cost-effectiveness with Locking Plate
    Kuwahara, Yutaro
    Takegami, Yasuhiko
    Mitsuya, So
    Tokutake, Katsuhiro
    Yamauchi, Kenichi
    Imagama, Shiro
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2023, 28 (02) : 205 - 213