High-Pitch Dual Spiral Cardiovascular Computed Tomography

被引:2
作者
Hetterich H. [1 ]
Wirth S. [1 ]
Johnson T.R. [1 ]
Bamberg F. [1 ,2 ]
机构
[1] Department of Radiology, Ludwig-Maximilians-University, Munich
[2] Department of Clinical Radiology, Ludwig-Maximilians University Munich, 81377 Munich
关键词
Cardiac CT; Coronary angiography; High-pitch; Low-dose;
D O I
10.1007/s12410-013-9199-z
中图分类号
学科分类号
摘要
High-pitch dual spiral computed tomography (CT) acquisitions are a relatively novel technical development characterized by significantly reduced acquisition time and radiation exposure by avoiding data oversampling. This approach may therefore overcome major limitations of current cardiovascular CT imaging and be applicable to a variety of clinical settings. Given the great potential, we review technical principles, summarize available early scientific evidence and identify limitations of the technique. © 2013 Springer Science+Business Media New York.
引用
收藏
页码:251 / 258
页数:7
相关论文
共 60 条
[1]  
Taylor A.J., Cerqueira M., Hodgson J.M., Et al., ACCF/SCCT/ACR/AHA/ASE/ASNC/NASCI/SCAI/SCMR 2010 appropriate use criteria for cardiac computed tomography. A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the Society of Cardiovascular Computed Tomography, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the American Society of Nuclear, J Am Coll Cardiol, 56, pp. 1864-1894, (2010)
[2]  
Einstein A.J., Henzlova M.J., Rajagopalan S., Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography, Jama, 298, pp. 317-323, (2007)
[3]  
Mayo J.R., Leipsic J.A., Radiation dose in cardiac CT, Ajr, 192, pp. 646-653, (2009)
[4]  
Scheffel H., Alkadhi H., Leschka S., Et al., Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance, Heart, 94, pp. 1132-1137, (2008)
[5]  
Stolzmann P., Leschka S., Scheffel H., Et al., Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose, Radiology, 249, pp. 71-80, (2008)
[6]  
Hausleiter J., Meyer T., Hermann F., Et al., Estimated radiation dose associated with cardiac CT angiography, Jama, 301, pp. 500-507, (2009)
[7]  
Lell M., Marwan M., Schepis T., Et al., Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience, Eur Radiol, 19, pp. 2576-2583, (2009)
[8]  
Jakobs T.F., Becker C.R., Ohnesorge B., Et al., Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation, Eur Radiol, 12, pp. 1081-1086, (2002)
[9]  
Hausleiter J., Meyer T., Tips to minimize radiation exposure, J Cardiovasc Comp Tomograph, 2, pp. 325-327, (2008)
[10]  
Paul J.F., Abada H.T., Strategies for reduction of radiation dose in cardiac multislice CT, Eur Radiol, 17, pp. 2028-2037, (2007)